Circuit Breakers

Results:
124,780
Manufacturer
Series
Approval Agency
Current Rating (Amps)
Illumination Voltage (Nominal)
Voltage Rating - DC
Voltage Rating - AC
Illumination
Number of Poles
Actuator Type
Breaker Type
Accessory Type
For Use With/Related Products
Mounting Type
Index Stops
Housing Material
Contact Finish
Current - Max
Actuator Length
Circuit per Deck
Energy
AC Outlets
Connector - AC Input
Contact Material
Features
Media Lines Protected
Voltage - Input
Connector - AC Output
Number of Positions
Number of Poles per Deck
Termination Style
Angle of Throw
Depth Behind Panel
Type
Overload Protection
Contact Timing
Cord Length
Region Utilized
Number of Decks
Results remainingļ¼š124,780
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesMounting TypeApproval AgencyVoltage Rating - ACVoltage Rating - DCIlluminationNumber of PolesIllumination Voltage (Nominal)Current Rating (Amps)Breaker TypeActuator Type
W28-XQ1A-0.25
1+
$1.5800
5+
$1.4922
10+
$1.4044
Quantity
5,119 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
W28
Panel Mount
-
250 V
32 V
-
1
-
250mA
Thermal
Push to Reset
W28-XQ1A-10
1+
$4.4500
5+
$4.2028
10+
$3.9556
Quantity
1,500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
W28
Panel Mount
-
250 V
32 V
-
1
-
10A
Thermal
Push to Reset
1610-H2-8A
CIRCUIT BREAKER THRM 8A 32VDC
1+
$11.7500
5+
$11.0972
10+
$10.4444
Quantity
1,177 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1610
Holder
UL1500
-
32 V
None
1
-
8A
Thermal
Push to Reset
4430.1201
CIR BRKR THRM 5A 240VAC 60VDC
1+
$30.2500
5+
$28.5694
10+
$26.8889
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
TA45
Panel Mount
CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
240 V
60 V
-
2
-
5A
Thermal
Rocker
1610-H2-20A
CIR BRKR THRM 20A 32VDC
1+
$11.5000
5+
$10.8611
10+
$10.2222
Quantity
620 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1610
Holder
UL1500
-
32 V
None
1
-
20A
Thermal
Push to Reset
1020035
CIRCUIT BRAKER 60A
Contact us
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
TMC 7
DIN Rail
-
277 V
-
None
3
-
60A
Thermal Magnetic
Lever
1410-L210-L2F1-S02-3.15A
CIR BRKR THRM 3.15A 250VAC 50VDC
1+
$16.3000
5+
$15.3944
10+
$14.4889
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1410-L2
PCB
CSA C22.2 No 235, IEC 60934, UL1077
250 V
50 V
None
1
-
3.15A
Thermal
Push to Reset
R10-S-SW-R01CV
1+
$38.7500
5+
$36.5972
10+
$34.4444
Quantity
400 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
SNAPAKĀ®
Panel Mount
-
-
-
-
1
-
-
Magnetic (Hydraulic Delay)
Rocker
W31-X2M1G-5
1+
$37.5000
5+
$35.4167
10+
$33.3333
Quantity
366 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
W31
Panel Mount
-
240 V
50 V
-
1
-
5A
Thermal
Toggle
1610-H2-5A
CIRCUIT BREAKER THRM 5A 32VDC
1+
$10.2500
5+
$9.6806
10+
$9.1111
Quantity
306 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1610
Holder
UL1500
-
32 V
None
1
-
5A
Thermal
Push to Reset
4430.2078
CIR BRKR THRM 10A 240VAC 60VDC
1+
$37.5000
5+
$35.4167
10+
$33.3333
Quantity
252 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
TA45
Panel Mount
CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
240 V
60 V
-
2
-
10A
Thermal
Rocker
GV3P40
TESYS MOTOR CB THO/MAG 30-40A EV
1+
$50.0000
5+
$47.2222
10+
$44.4444
Quantity
156 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
-
-
-
-
-
GV3P50
TESYS 3P MOTOR CB THO/MAG 37-50A
1+
$112.5000
5+
$106.2500
10+
$100.0000
Quantity
120 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
-
-
-
-
-
CTB-B-B-04
CIR BRKR THRM 4A 250VAC 50VDC
1+
$9.5000
5+
$8.9722
10+
$8.4444
Quantity
110 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
CTB
Panel Mount
CE, cUL, UL1077, VDE
250 V
50 V
None
1
-
4A
Thermal
Push to Reset
1410-L110-L1F1-S01-0.63A
CIR BRKR THRM 630MA 250VAC 50VDC
1+
$14.7500
5+
$13.9306
10+
$13.1111
Quantity
100 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1410-L1
Through Hole
CSA C22.2 No 235, IEC 60934, UL1077
250 V
50 V
None
1
-
630mA
Thermal
Push to Reset
W31-X2M1G-15
1+
$30.0000
5+
$28.3333
10+
$26.6667
Quantity
60 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
W31
Panel Mount
-
240 V
50 V
-
1
-
15A
Thermal
Toggle
W92-X112-10
1+
$200.2250
5+
$189.1014
10+
$177.9778
Quantity
50 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
W9
Panel Mount
-
277 V
-
-
2
-
10A
Magnetic (Hydraulic Delay)
Lever
1D20UR
1D20UR 20A MCB D CHAR 1 P 277VAC
1+
$31.5250
5+
$29.7736
10+
$28.0222
Quantity
45 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
UR
DIN Rail
CE, cURus, UL1077
277 V
-
None
1
-
20A
Thermal Magnetic
Lever
MT1-B-14-610-1-A24-B-J
1+
$102.9169
5+
$97.1992
10+
$91.4816
Quantity
34 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
M
Panel Mount
CCC, TUV, UL489A
250 V
80 V
None
1
-
10A
Magnetic (Hydraulic Delay)
Push-Pull
1610-21-6A
CIRCUIT BREAKER THRM 6A 32VDC
1+
$23.3775
5+
$22.0788
10+
$20.7800
Quantity
20 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
1610
Holder
UL1500
-
32 V
None
1
-
6A
Thermal
Push to Reset

AboutĀ Ā Circuit Breakers

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. It serves as a crucial safety device in electrical systems by interrupting the flow of current when a fault occurs. When an abnormal current condition such as an overload or short circuit occurs, the circuit breaker detects it through a built-in sensing mechanism. This mechanism is typically based on magnetic or thermal principles. The sensing element monitors the current passing through the circuit and triggers the circuit breaker to trip when it exceeds a predetermined threshold. Upon detecting a fault, the circuit breaker swiftly interrupts the flow of electricity by opening its contacts. This action effectively isolates the faulty section of the circuit, preventing further damage to the system or potential hazards like fires or electrocution. By cutting off the current flow, the circuit breaker protects sensitive equipment and wiring from excessive heat and prevents the risk of electrical fires. One of the significant advantages of a circuit breaker over a fuse is its ability to be reset. After a fault has been resolved, the circuit breaker can be manually or automatically reset to restore normal operation. This feature eliminates the need for replacement, as is the case with fuses that must be replaced after they operate. It saves time and cost associated with replacing fuses, making circuit breakers a more convenient and economical choice. In addition to their protective function, circuit breakers also provide selective coordination in complex electrical systems. They are designed with various ratings, including current rating, voltage rating, and fault-breaking capacity, to suit different applications and ensure optimal performance. Overall, circuit breakers are indispensable components in electrical systems, safeguarding against overloads and short circuits while offering the flexibility of resetting for uninterrupted operation. Their ability to protect valuable equipment and prevent electrical hazards makes them an essential part of modern electrical infrastructure.