Monitor - Relay Output

Results:
1,159
Manufacturer
Series
Trip Range
Voltage - Supply
Delay Time
Contact Rating @ Voltage
Type
Circuit
Trip Status
Mounting Type
Output Type
Termination Style
Number of Outputs and Type
Number of Inputs and Type
For Use With/Related Products
Features
Results remaining1,159
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
K8AK-TH11S 24VAC/DC
TEMP MONITORING RELAY TC/RTD
1+
$57.9021
5+
$54.6853
10+
$51.4685
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Temperature Monitoring
-
-
No Delay
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
3UG4633-1AL30
DIGITAL MONITORING RELAY
1+
$193.8462
5+
$183.0769
10+
$172.3077
Quantity
5 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
SIRIUS 3UG4
Voltage Sensing AC/DC
-
17 ~ 275V AC/DC
0.1 Sec ~ 20 Sec
17 ~ 275VAC/DC
Relay
SPDT (1 Form C)
-
K8AB-VW2 200/230VAC
REL AC/DC VOLT SENS 200-230VAC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AB-VW
Voltage Sensing AC/DC
-
1 ~ 150V AC/DC
0.1 Sec ~ 30 Sec
200 ~ 230VAC
Relay
SPDT (1 Form C) x 2
6A @ 250VAC
1336408
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Voltage Asymmetry, Phase Loss, Phase Sequence
Energized High
160 ~ 690V DC
0 Sec ~ 99.9 Sec
24 ~ 240VDC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336404
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Voltage Asymmetry, Phase Loss, Phase Sequence
Energized High
160 ~ 690V DC
0 Sec ~ 99.9 Sec
24 ~ 240VDC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336527
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Temperature Monitoring
Energized High
-
No Delay
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336523
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Temperature Monitoring
Energized High
-
No Delay
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336412
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Phase Loss, Phase Sequence, Voltage Asymmetry, Voltage Sensing AC/DC
Energized High
160 ~ 690V AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336410
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Phase Loss, Phase Sequence, Voltage Asymmetry, Voltage Sensing AC/DC
Energized High
160 ~ 690V AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336512
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Current Sensing AC/DC
Energized High
0 ~ 10A AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336510
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Current Sensing AC/DC
Energized High
0 ~ 10A AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336426
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Voltage Sensing AC/DC
Energized High
0 ~ 600V AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336507
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Voltage Sensing AC/DC
Energized High
0 ~ 600V AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
1336547
MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
MACX
Phase Loss, Phase Sequence, Voltage Asymmetry, Voltage Sensing AC/DC
Energized High
480 ~ 900V AC/DC
0 Sec ~ 99.9 Sec
24 ~ 240VAC/DC
Relay
DPDT (2 Form C)
8A @ 250VAC
831VS24D
VOLTAGE SENSING RY, SPDT, 15A, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Voltage Sensing DC
Energized High/Low
18 ~ 30V DC
0 ~ 10 Sec
6 ~ 30VDC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC
831VS120A
VOLTAGE SENSING RY, SPDT, 15A, 1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Voltage Sensing AC
Energized High/Low
85 ~ 150V AC
0 ~ 10 Sec
150VAC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC
841CS2UNI
CURRENT SENSING RY,SPDT,15A,24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Current Sensing AC
Energized High/Low
0.2 ~ 2A AC
0 ~ 10 Sec
24 ~ 240VAC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC
841CS5UNI
CURRENT SENSING RY, SPDT, 15A,24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Current Sensing AC
Energized High/Low
0.5 ~ 5A AC
0 ~ 10 Sec
24 ~ 240VAC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC
841CS1UNI
CURRENT SENSING RY, SPDT, 15A,24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Current Sensing AC
Energized High/Low
0.1 ~ 1.0A AC
0 ~ 10 Sec
24 ~ 240VAC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC
831VS240A
VOLTAGE SENSING RY, SPDT, 15A, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Legacy
Voltage Sensing AC
Energized High/Low
160 ~ 276V AC
0 ~ 10 Sec
276VAC
Relay
SPDT (1 Form C)
15A @ 240VAC/24VDC

Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.