Gas Discharge Tube Arresters (GDT)

Results:
4,345
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Package / Case
Impulse Discharge Current (8/20µs)
Tolerance
Mounting Type
Number of Poles
Fail Short
Voltage - Continuous Operating (Max) (MCOV)
Operating Temperature
Form
Approval Agency
Voltage - Protection Rating (VPR)
Current - Discharge (Max) (8/20µS)
Current - Discharge (Nom) (8/20µS)
Type
Voltage - Protection Level (VP) (2416)
Current - Short Circuit Rating (SCRR)
Features
Results remaining4,345
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTolerancePackage / CaseNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail Short
B88069X9231T203
GDT 90V 2KA 2 POLE SURFACE MOUNT
1+
$1.2587
5+
$1.1888
10+
$1.1189
Quantity
212,095 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±30%
1812 (4532 Metric)
2
S30-A90X
90 V
2000A (2kA)
No
B88069X4211T902
GDT 300V 2.5KA 2 POLE SMD
1+
$0.3776
5+
$0.3566
10+
$0.3357
Quantity
130,400 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±15%
2-SMD Cylinder Square End
2
ES
300 V
2500A (2.5kA)
No
2035-09-SM-RPLF
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.4154
5+
$0.3923
10+
$0.3692
Quantity
79,500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2-SMD Cylinder Square End
2
2035-SM
90 V
5000A (5kA)
No
B88069X9800B502
GDT 230V 10KA 3 POLE TH
1+
$0.8308
5+
$0.7846
10+
$0.7385
Quantity
63,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
T33
230 V
10000A (10kA)
No
B88069X1640T902
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.1510
5+
$0.1427
10+
$0.1343
Quantity
40,500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2-SMD Cylinder Square End
2
M50
90 V
5000A (5kA)
No
2026-09-C2LF
GDT 90V 20KA 3 POLE THROUGH HOLE
1+
$3.0210
5+
$2.8531
10+
$2.6853
Quantity
36,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
TRIGARD® 2026
90 V
20000A (20kA)
No
B88069X8300B502
GDT 90V 10KA 3 POLE THROUGH HOLE
1+
$0.5035
5+
$0.4755
10+
$0.4476
Quantity
32,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder, 3 Lead (Radial Bend)
3
T83
90 V
10000A (10kA)
No
SL1002A350SM
GDT 350V 5KA 2 POLE SMD
1+
$0.4531
5+
$0.4280
10+
$0.4028
Quantity
27,054 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2-SMD Cylinder Square End
2
SL1002A
350 V
5000A (5kA)
No
B88069X4651S102
GDT 1000V 2KA 2 POLE TH
1+
$0.7552
5+
$0.7133
10+
$0.6713
Quantity
21,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EM
1000 V
2000A (2kA)
No
SL1003A090R
GDT 90V 10KA 3 POLE THROUGH HOLE
1+
$0.8811
5+
$0.8322
10+
$0.7832
Quantity
15,130 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
Axial Cylinder, 3 Lead (Radial Bend)
3
SL1003A
90 V
10000A (10kA)
No
2035-35-SM-RPLF
GDT 350V 5KA 2 POLE SMD
1+
$0.4028
5+
$0.3804
10+
$0.3580
Quantity
14,574 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±15%
2-SMD Cylinder Square End
2
2035-SM
350 V
5000A (5kA)
No
2035-09-BT1LF
GDT 90V 5KA 2 POLE THROUGH HOLE
1+
$0.7552
5+
$0.7133
10+
$0.6713
Quantity
14,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
2035
90 V
5000A (5kA)
No
B88069X2311S102
GDT 3600V 2KA 2 POLE TH
1+
$0.5538
5+
$0.5231
10+
$0.4923
Quantity
12,165 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EM
3600 V
2000A (2kA)
No
B88069X0180S102
GDT 75V 5KA 2 POLE THROUGH HOLE
1+
$1.6993
5+
$1.6049
10+
$1.5105
Quantity
11,638 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EC
75 V
5000A (5kA)
No
SL1002A090SM
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$0.3776
5+
$0.3566
10+
$0.3357
Quantity
10,478 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2-SMD Cylinder Square End
2
SL1002A
90 V
5000A (5kA)
No
GTCS35-750M-R05-2
GDT 75V 5KA 3 POLE SURFACE MOUNT
1+
$1.1329
5+
$1.0699
10+
$1.0070
Quantity
10,089 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
3-SMD Cylinder Square End
3
GT
75 V
5000A (5kA)
No
B88069X2140S102
GDT 800V 10KA 2 POLE TH
1+
$2.1701
5+
$2.0495
10+
$1.9290
Quantity
10,070 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±15%
Axial Cylinder
2
A71
800 V
10000A (10kA)
No
2051-15-SM-RPLF
GDT 150V 2KA 2 POLE SMD
1+
$0.6294
5+
$0.5944
10+
$0.5594
Quantity
9,922 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±30%
1812 (4532 Metric)
2
2051
150 V
2000A (2kA)
No
2017-09-SMC-RPLF
GDT 90V 10KA 2 POLE SMD VERTICAL
1+
$1.5105
5+
$1.4266
10+
$1.3427
Quantity
8,350 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount Vertical
±20%
Disc 8.00mm Tabbed SMD
2
2017
90 V
10000A (10kA)
No
B88069X5600S102
GDT 2000V 2KA 2 POLE TH
1+
$0.2769
5+
$0.2615
10+
$0.2462
Quantity
8,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
Axial Cylinder
2
EM
2000 V
2000A (2kA)
No

Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.