Signal Conditioners and Isolators

Results:
911
Manufacturer
Series
Input Range (Current, Voltage)
Input Range (Additional)
Voltage - Supply
Output Range
Isolation
Operating Temperature
Features
Input Type
Type
Output Type
Termination Style
Mounting Type
Results remaining911
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeVoltage - SupplySeriesTermination StyleIsolationTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output TypeOutput Range
2902037
MINI MCR-2-UI-UI
1+
$276.9231
5+
$261.5385
10+
$246.1538
Quantity
5 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
MINI MCR
Screw Terminal
-
Signal Conditioner
Current, Voltage
±20mA, ±30V (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
2902023
MINI MCR-2-U-I0-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
MINI MCR
Screw Terminal
-
Signal Conditioner
Voltage
0 ~ 10V
-
Current
0 ~ 20mA
2517450000
PICOPAK-CI-CO-LP-S
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
Loop Powered
-
Screw Terminal
-
Passive Isolator
Current
4 ~ 20mA
-
Current
4 ~ 20mA
3RS70002AE00
0-10V TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Spring Terminal
50V
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Voltage
0 ~ 10V
3RS70021CE00
0-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Screw Terminal
50V
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Current
0 ~ 20mA
3RS70001CE00
0-10V TO 0-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Screw Terminal
50V
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Current
0 ~ 20mA
3RS70032AE00
4-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Spring Terminal
50V
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
3RS70032CE00
4-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Spring Terminal
50V
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
0 ~ 20mA
3RS70031AE00
4-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Screw Terminal
50V
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
3RS70021AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
3RS7
Screw Terminal
50V
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
ADAM-3013-AE
ISOLATED RTD-INPUT MODULE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
0°C ~ 70°C
DIN Rail
24VDC
ADAM-3013
Screw Terminal
1000V
Isolation Amplifier
Temperature
-
-100°C ~ 600°C
-
-
2902022
MINI MCR-2-U-I0
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
MINI MCR
Screw Terminal
-
Signal Conditioner
Voltage
0 ~ 10V
-
Current
0 ~ 20mA
2902000
MINI MCR-2-I0-U
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
MINI MCR
Screw Terminal
-
Signal Conditioner
Current
0 ~ 20mA
-
Voltage
0 ~ 10V
1176050000
SIGNAL CONVERTER/DISCONNECTOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
Loop Powered
ACT20M
Screw Terminal
300V (Working), 2500V (Test)
Signal Conditioner
Current
4 ~ 20mA
-
Current
4 ~ 20mA
1176080000
SIGNAL CONVERTER/DISCONNECTOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
Loop Powered
ACT20M
Screw Terminal
300V (Working), 2500V (Test)
Passive Isolator
Current
0 ~ 20mA
-
Current
0 ~ 20mA
1375470000
ACT20M-BAI-2AO-S
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
-
Screw Terminal
-
Signal Conditioner
Current, Voltage
±20mA, ±10V (Configurable)
-
Current, Voltage
±20mA, 0 ~ 10V (Configurable)
2489910000
CONDITIONER SGNL RAIL MNT AC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
16.8 ~ 31.2V
ACT20P
Screw Terminal
300V (Working), 4000V (Test)
Signal Conditioner
Current
0 ~ 10A (Configurable)
-
Current, Voltage
±20mA, ±10V (Configurable)
857-414
ISOLATION AMPLIFIER; VOLTAGE INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
857
Spring Terminal
2500V (Test)
Isolation Amplifier
Voltage
0 ~ 10V
0 ~ 100kOhm
Current
4 ~ 20mA
7760054306
ANLG SIGNAL COND/ISO AC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 65°C
DIN Rail
24 ~ 240VAC/DC
ACT20P
Screw Terminal
600V (Working), 2000V (Test)
Signal Conditioner
Voltage
0 ~ 660VDC, 0 ~ 440VAC (Configurable)
-
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
2489680000
CONDITIONER SIGNAL DINRAIL MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 85°C
DIN Rail
20 ~ 30VDC
ACT20P
Spring Terminal
300V (Working), 2000V (Test)
Signal Conditioner
Current
0 ~ 20mA
-
Current
0 ~ 20mA

Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.