Eaton-Electronics Division

Eaton-Electronics Division

Eaton-Electronics Division is a division of Eaton Corporation, specializing in the design, development, and production of electronic components and systems for a wide range of industries. With a strong focus on innovation and quality, the division offers an extensive portfolio of products including sensors, switches, relays, connectors, and power management solutions. These products are designed to meet the demanding requirements of industries such as automotive, aerospace, industrial automation, and telecommunications. Eaton-Electronics Division is known for its advanced manufacturing capabilities, cutting-edge technology, and commitment to customer satisfaction. With a global footprint and a dedicated team of engineers and technicians, the division strives to provide reliable, high-performance solutions that enhance the functionality and efficiency of electronic systems.

Current Sense Transformers

Results:
70
Series
DC Resistance (DCR)
Inductance
Turns Ratio - Primary:Secondary
Termination Style
Height - Seated (Max)
Current Rating (Amps)
Size / Dimension
Ratings
Frequency Range
Current Ratio
Mounting Type
Type
ET (Volt-Time)
Results remaining70
Applied Filters:
Eaton-Electronics Division
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeInductanceHeight - Seated (Max)Termination StyleRatingsCurrent Rating (Amps)ET (Volt-Time)SeriesFrequency RangeTypeCurrent RatioDC Resistance (DCR)Size / DimensionTurns Ratio - Primary:Secondary
ECST1V0805-1125-R
TRANSF CURRENT SENS 125:1 10A SM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
3 mH
0.217" (5.50mm)
Gull Wing
-
10 A
-
ECST
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 11.5Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
125:1
ECST1V0703-1020-R
TRANSF CURRENT SENSE 20:1 9A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
53 µH
0.118" (3.00mm)
J Lead
-
9 A
-
ECST
50kHz ~ 1MHz
Invasive
-
1.5mOhm Primary, 420mOhm Secondary Max
0.283" L x 0.205" W (7.20mm x 5.20mm)
20:1
ECST1V0703-1050-R
TRANSF CURRENT SENSE 50:1 9A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
333 µH
0.118" (3.00mm)
J Lead
-
9 A
-
ECST
50kHz ~ 1MHz
Invasive
-
1.5mOhm Primary, 2.76Ohm Secondary Max
0.283" L x 0.205" W (7.20mm x 5.20mm)
50:1
ECST1V0703-1150-R
TRANSF CURRENT SENS 150:1 9A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
2.99 mH
0.118" (3.00mm)
J Lead
-
9 A
-
ECST
50kHz ~ 1MHz
Invasive
-
1.5mOhm Primary, 22.3Ohm Secondary Max
0.283" L x 0.205" W (7.20mm x 5.20mm)
150:1
ECSTA1V0805-1060-R
TRANSF CURRENT SENS 60:1 10A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
730 µH
0.217" (5.50mm)
Gull Wing
AEC-Q200
10 A
-
ECSTA
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 2.3Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
60:1
ECSTA1V0805-1125-R
TRANSF CURRENT SENS 125:1 10A SM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
3 mH
0.217" (5.50mm)
Gull Wing
AEC-Q200
10 A
-
ECSTA
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 11.5Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
125:1
ECST1V0805-1050-R
TRANSF CURRENT SENS 50:1 10A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
500 µH
0.217" (5.50mm)
Gull Wing
-
10 A
-
ECST
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 1.85Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
50:1
ECST1V0805-1100-R
TRANSF CURRENT SENS 100:1 10A SM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
2 mH
0.217" (5.50mm)
Gull Wing
-
10 A
-
ECST
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 5.5Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
100:1
ECSTA1V0805-1050-R
TRANSF CURRENT SENS 50:1 10A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
500 µH
0.217" (5.50mm)
Gull Wing
AEC-Q200
10 A
-
ECSTA
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 1.85Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
50:1
ECSTA1V0805-1100-R
TRANSF CURRENT SENS 100:1 10A SM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
2 mH
0.217" (5.50mm)
Gull Wing
AEC-Q200
10 A
-
ECSTA
50kHz ~ 1MHz
Invasive
-
700mOhm Primary, 5.5Ohm Secondary Max
0.330" L x 0.315" W (8.38mm x 8.00mm)
100:1

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.