Simpson Electric

Simpson Electric

Simpson Electric Company is a prominent producer of digital panel meters, analog panel meters, smart meters, and test equipment. Our wide range of products caters to various markets such as industrial, power management, and test/measurement.

Current Sense Transformers

Results:
28
Series
Current Rating (Amps)
Turns Ratio - Primary:Secondary
Current Ratio
Height - Seated (Max)
Size / Dimension
Frequency Range
Termination Style
Mounting Type
Type
DC Resistance (DCR)
Ratings
Inductance
ET (Volt-Time)
Results remaining28
Applied Filters:
Simpson Electric
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesTermination StyleMounting TypeFrequency RangeRatingsDC Resistance (DCR)ET (Volt-Time)TypeCurrent Rating (Amps)Turns Ratio - Primary:SecondaryCurrent RatioSize / DimensionHeight - Seated (Max)Inductance
02459
CURRENT XFMR, DONUT, 750/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
750 A
150:1
-
4.500" Dia (114.30mm)
1.090" (27.69mm)
-
37026
CURRENT TRANS. 3 PHASE 50:5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Stud
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
50:5
7.130" L x 2.220" W (181.10mm x 56.39mm)
3.220" (81.79mm)
-
37027
CURRENT TRANS. 3 PHASE 100:5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Stud
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
100:5
7.130" L x 2.220" W (181.10mm x 56.39mm)
3.220" (81.79mm)
-
37022
CURRENT XFMR, SCREW, 200/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Terminal Block
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
-
3.780" L x 3.530" W (96.01mm x 89.66mm)
2.150" (54.61mm)
-
02303
CURRENT XFMR, DONUT, 600/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
600 A
120:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
37023
CURRENT XFMR, SCREW, 300/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Terminal Block
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
-
3.780" L x 3.530" W (96.01mm x 89.66mm)
2.150" (54.61mm)
-
01293
CURRENT XFMR, DONUT, 50/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
50 A
10:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01306
CURRENT XFMR, DONUT, 75/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
75 A
15:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01313
CURRENT XFMR, DONUT, 250/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
250 A
50:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01299
CURRENT XFMR, DONUT, 200/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
200 A
40:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01305
CURRENT XFMR, DONUT, 400/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
400 A
80:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01300
CURRENT XFMR, DONUT, 300/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
300 A
60:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01298
CURRENT XFMR, DONUT, 150/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
150 A
30:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
01297
CURRENT XFMR, DONUT, 100/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
100 A
20:1
-
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
37024
CURRENT XFMR, SCREW, 500/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Terminal Block
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
-
3.780" L x 3.530" W (96.01mm x 89.66mm)
2.150" (54.61mm)
-
02304
CURRENT XFMR, DONUT, 1000/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
1000 A
200:1
-
4.500" Dia (114.30mm)
1.090" (27.69mm)
-
01301
CURRENT XFMR, DONUT, 500/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Wire Leads
Free Hanging (In-Line)
-
-
-
-
Non-Invasive (Solid Core)
500 A
100:1
500:5
3.560" Dia (90.42mm)
1.100" (27.94mm)
-
37025
CURRENT XFMR, SCREW, 1000/5 AMPS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Stud
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
-
3.780" L x 3.530" W (96.01mm x 89.66mm)
2.150" (54.61mm)
-
37029
CURRENT TRANS, 3 PHASE 200:5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Stud
Chassis Mount
50Hz ~ 400Hz
-
-
-
Non-Invasive (Solid Core)
-
-
200:5
7.130" L x 2.220" W (181.10mm x 56.39mm)
3.220" (81.79mm)
-
37032
SPLIT CORE CURRENT XFMR; 200/5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Terminal Block
DIN Rail
50Hz ~ 60Hz
-
-
-
Non-Invasive (Split Core)
200 A
-
-
3.661" L x 1.575" W (93.00mm x 40.00mm)
4.173" (106.00mm)
-

About  Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.