Current Sense Transformers

Results:
1,492
Manufacturer
Series
DC Resistance (DCR)
Size / Dimension
Height - Seated (Max)
Inductance
ET (Volt-Time)
Current Rating (Amps)
Current Ratio
Turns Ratio - Primary
Frequency Range
Turns Ratio - Primary:Secondary
Termination Style
Mounting Type
Type
For Use With/Related Products
Ratings
Features
Applications
Material
Accessory Type
Inner Diameter - Recovered
Storage/Refrigeration Temperature
License Length
Wire Entry Location
Shrinkage Ratio
Tool Method
Operating System
Wire Gauge or Range - AWG
Operating Temperature
Color
Recovered Wall Thickness
License - User Details
Ratcheting
Grade
Edition
Media Delivery Type
Qualification
Shrink Temperature
Thread/Screw/Hole Size
Specifications
Inner Diameter - Supplied
Height
Wire Gauge or Range - mm²
Tool Type
Length - Center to Center
Tool Type Feature
Length
Shelf Life
Results remaining1,492
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleRatingsHeight - Seated (Max)ET (Volt-Time)Current Rating (Amps)SeriesFrequency RangeTypeInductanceCurrent RatioDC Resistance (DCR)Size / DimensionTurns Ratio - Primary
PB0026NLT
CURR SENSE XFMR 100:1 35A SMD
1+
$2.5352
5+
$2.3944
10+
$2.2535
Quantity
145 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.394" (10.00mm)
-
35 A
PB002XNL
50kHz ~ 500kHz
Invasive
5.6 mH
-
0.42mOhm Primary, 1.4Ohm Secondary
0.591" L x 0.784" W (15.00mm x 19.91mm)
Secondary:100:1
PA1005.050NLT
CURR SENSE XFMR 1:50 20A SMD
1+
$5.0704
5+
$4.7887
10+
$4.5070
Quantity
70 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.217" (5.50mm)
-
20 A
PA1005.XXXNL
50kHz ~ 1MHz
Invasive
500 µH
-
0.75mOhm Primary, 1.5Ohm Secondary
0.284" L x 0.330" W (7.21mm x 8.38mm)
Secondary:1:50
2277093
CURR SENSE XFMR 1:80 400A DIN RL
1+
$30.4225
5+
$28.7324
10+
$27.0423
Quantity
36 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
Terminal Block
-
3.150" (80.00mm)
-
400 A
PACT
50Hz ~ 60Hz
Non-Invasive (Solid Core)
-
-
-
2.362" L x 1.181" W (60.00mm x 30.00mm)
Secondary:-
MR-2
CURR SENSE XFMR CHAS MNT
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads
-
0.327" (8.30mm)
-
10 A
MR
50/60Hz
Non-Invasive (Solid Core)
-
-
30Ohm
0.972" L x 0.858" W (24.70mm x 21.80mm)
Secondary:-
53070C
CURR SENSE XFMR 1:70 10A SMD
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.213" (5.40mm)
-
-
5300
50kHz ~ 500kHz
Invasive
980 µH
-
7mOhm Primary, 4.5Ohm Secondary
0.283" L x 0.327" W (7.20mm x 8.30mm)
Secondary:1:70
CR8449-2500-N
CURR SENSE XFMR 50A IN-LINE
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Free Hanging (In-Line)
Wire Leads
-
0.669" (17.00mm)
-
50 A
CR8400
20Hz ~ 1kHz
Non-Invasive (Solid Core)
-
2500:1
187Ohm
1.252" L x 1.024" W (31.80mm x 26.00mm)
Secondary:-
FIS121NL
CURR SENSE XFMR 1:200 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.803" (20.40mm)
700VµS
-
FIS
200kHz Max
Non-Invasive (Solid Core)
94.5 mH
-
4.5Ohm Max
0.677" L x 0.375" W (17.20mm x 9.53mm)
Secondary:1:200
PE-63588NL
CURR SENSE XFMR 20A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.700" (17.78mm)
-
20 A
THT
20kHz ~ 200kHz
Invasive
80 mH
200:1
200Ohm Primary, 4.5Ohm Secondary
0.900" L x 0.700" W (22.86mm x 17.78mm)
Secondary:-
P0582NL
CURR SENSE XFMR 100:1:1 35A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.750" (19.05mm)
-
35 A
THT
50kHz ~ 500kHz
Invasive
19 mH
-
1.4Ohm Primary, 1.7mOhm Secondary
0.810" L x 0.580" W (20.57mm x 14.73mm)
Secondary:100:1:1
PE-51717NL
CURR SENSE XFMR 20A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.700" (17.78mm)
-
20 A
-
20kHz ~ 200kHz
Non-Invasive (Solid Core)
5 mH
50CT:1
-
0.900" L x 0.700" W (22.86mm x 17.78mm)
Secondary:-
PE-51687NL
CURR SENSE XFMR 20A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.800" (20.32mm)
-
20 A
THT
20kHz ~ 200kHz
Invasive
20 mH
100:1
100Ohm Primary, 1.4Ohm Secondary
0.670" L x 0.390" W (17.01mm x 9.90mm)
Secondary:-
CSE184L
CURR SENSE XFMR 1A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
0.709" (18.00mm)
-
1 A
-
50Hz ~ 400Hz
Invasive
-
-
125mOhm Primary, 23Ohm Secondary
0.846" L x 0.945" W (21.50mm x 24.00mm)
Secondary:-
B82801C0565A100
CURR SENSE XFMR 1:100 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.394" (10.00mm)
-
-
B82801C
50kHz ~ 500kHz
Invasive
5.6 mH
-
0.28mOhm Primary, 1Ohm Secondary
0.560" L x 0.530" W (14.22mm x 13.46mm)
Secondary:1:100
7492540200
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
AEC-Q200
0.413" (10.50mm)
496Vµs
40 A
MID-CST
1MHz
Invasive
22.4 mH
-
0.28mOhm
0.570" L x 0.524" W (14.48mm x 13.30mm)
Secondary:1:200
PE-68280NLT
CURR SENSE XFMR 1:1:100 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
-
0.280" (7.11mm)
-
-
PE-68XXXNL
50kHz ~ 500kHz
Invasive
14.8 mH
-
1.15mOhm Primary, 930mOhm Secondary
0.495" L x 0.490" W (12.57mm x 12.45mm)
Secondary:1:1:100
B82801A1824A100
CURR SENSE XFMR 1:100 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
J Lead
-
0.138" (3.50mm)
-
-
B82801A
50kHz ~ 1MHz
Invasive
820 µH
-
2.5mOhm Primary, 8.7Ohm Secondary
0.185" L x 0.138" W (4.70mm x 3.50mm)
Secondary:-
B82801B0925A200
CURR SENSE XFMR 1:200 20A SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.200" (5.08mm)
100VµS
20 A
B82801B
50kHz ~ 1MHz
Invasive
8 mH
-
0.6mOhm Primary, 33.24Ohm Secondary
0.280" L x 0.320" W (7.11mm x 8.13mm)
Secondary:1:200
PA0368.100NLT
CURR SENSE XFMR 1:100 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
-
0.134" (3.40mm)
-
-
PA0368NL
50kHz ~ 1MHz
Invasive
6.7 mH
-
4mOhm Primary, 1.6Ohm Secondary
0.325" L x 0.325" W (8.25mm x 8.25mm)
Secondary:1:100
CR8459-2000-N
CURR SENSE XFMR 200A IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Free Hanging (In-Line)
Wire Leads
-
0.689" (17.50mm)
-
200 A
CR8400
20Hz ~ 1kHz
Non-Invasive (Solid Core)
-
2000:1
74Ohm
2.362" L x 1.890" W (60.00mm x 48.00mm)
Secondary:-
B82801B0305A125
CURR SENSE XFMR 1:125 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
0.200" (5.08mm)
-
-
B82801B
50kHz ~ 1MHz
Invasive
3 mH
-
0.8mOhm Primary, 6.5Ohm Secondary
0.280" L x 0.320" W (7.11mm x 8.13mm)
Secondary:1:125

Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.