1,492
Manufacturer
Series
DC Resistance (DCR)
Size / Dimension
Height - Seated (Max)
Inductance
ET (Volt-Time)
Current Rating (Amps)
Current Ratio
Turns Ratio - Primary
Frequency Range
Turns Ratio - Primary:Secondary
Termination Style
Mounting Type
Type
For Use With/Related Products
Ratings
Features
Applications
Material
Accessory Type
Inner Diameter - Recovered
Storage/Refrigeration Temperature
License Length
Wire Entry Location
Shrinkage Ratio
Tool Method
Operating System
Wire Gauge or Range - AWG
Operating Temperature
Color
Recovered Wall Thickness
License - User Details
Ratcheting
Grade
Edition
Media Delivery Type
Qualification
Shrink Temperature
Thread/Screw/Hole Size
Specifications
Inner Diameter - Supplied
Height
Wire Gauge or Range - mm²
Tool Type
Length - Center to Center
Tool Type Feature
Length
Shelf Life
Results remaining1,492
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeTermination StyleRatingsSeriesCurrent Rating (Amps)Frequency RangeTypeInductanceET (Volt-Time)Current RatioDC Resistance (DCR)Size / DimensionHeight - Seated (Max)Turns Ratio - Primary
CST306-3T
CURR SENSE XFMR 25A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CST
25 A
20kHz ~ 200kHz
Non-Invasive (Solid Core)
55 mH
2000VµS
200CT:1
3.75Ohm Max
0.690" L x 0.385" W (17.53mm x 9.78mm)
0.915" (23.24mm)
Secondary:-
B82801B0324A040
CURR SENSE XFMR 1:40 SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
Gull Wing
-
B82801B
-
50kHz ~ 1MHz
Invasive
320 µH
-
-
0.8mOhm Primary, 1.14Ohm Secondary
0.280" L x 0.320" W (7.11mm x 8.13mm)
0.200" (5.08mm)
Secondary:1:40
CCT272440-80-10-00
CURR SENSE XFMR 80A CHAS MNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Wire Leads with Connector
-
CCT
80 A
50/60Hz
Non-Invasive (Split Core)
-
-
3000:1
352Ohm
1.201" L x 1.083" W (30.50mm x 27.50mm)
1.634" (41.50mm)
Secondary:-
CR2550-G
CURR SENSE XFMR IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Free Hanging (In-Line)
-
-
CR2550
-
50Hz ~ 400Hz
Non-Invasive (Solid Core)
-
-
-
-
1.094" L x 0.866" W (27.80mm x 22.00mm)
-
Secondary:-
CT-1100
CURR SENSE XFMR 100A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CT
100 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
21.3Ohm
1.752" L x 0.563" W (44.50mm x 14.30mm)
1.752" (44.50mm)
Secondary:-
T60404E4624X501
CURRENT TRANSFORMER, 60A 2500:1,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
-
60 A
50Hz
Non-Invasive (Solid Core)
3 H
-
2500:1
55Ohm
1.220" L x 0.551" W (31.00mm x 14.00mm)
1.240" (31.50mm)
Secondary:1:2500
CST-1030
CURR SENSE XFMR 30A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CST
30 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
46Ohm
1.189" L x 0.563" W (30.20mm x 14.30mm)
1.189" (30.20mm)
Secondary:-
T60404E4626X501
CURRENT TRANSFORMER, 100A 2500:1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
-
100 A
50Hz
Non-Invasive (Solid Core)
2.1 H
-
2500:1
44Ohm
1.339" L x 0.551" W (34.00mm x 14.00mm)
1.339" (34.00mm)
Secondary:1:2500
AC1100
CURR SENSE XFMR 100A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
AC
100 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
21.3Ohm
1.752" L x 0.563" W (44.50mm x 14.30mm)
1.752" (44.50mm)
Secondary:-
CT-1010
CURR SENSE XFMR 10A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CT
10 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
41.8Ohm
0.937" L x 0.438" W (23.80mm x 11.12mm)
0.937" (23.80mm)
Secondary:-
AC1015
CURR SENSE XFMR 15A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
AC
15 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
41.8Ohm
0.937" L x 0.438" W (23.80mm x 11.12mm)
0.937" (23.80mm)
Secondary:-
PE-67050NL
CURR SENSE XFMR 35A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
-
35 A
10kHz ~ 200kHz
Invasive
5 mH
-
50:1
15Ohm Primary, 700mOhm Secondary
0.565" L x 0.750" W (14.35mm x 19.05mm)
0.750" (19.05mm)
Secondary:-
CT-1030
CURR SENSE XFMR 30A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CT
30 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
48Ohm
1.189" L x 0.563" W (30.20mm x 14.30mm)
1.189" (30.20mm)
Secondary:-
CST206-1T
CURR SENSE XFMR 110A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CST
110 A
20kHz ~ 200kHz
Non-Invasive (Solid Core)
14 mH
2000VµS
100:1
580mOhm Max
1.075" L x 0.400" W (27.31mm x 10.16mm)
1.225" (31.12mm)
Secondary:-
T60404E4622X503
CURRENT TRANSFORMER, 20A 2000:1,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
-
20 A
50Hz ~ 60Hz
Non-Invasive (Solid Core)
238 H
-
2000:1
114Ohm
0.965" L x 0.484" W (24.50mm x 12.30mm)
0.994" (25.25mm)
Secondary:1:2000
CT-1005
CURR SENSE XFMR 5A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CT
5 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
41.8Ohm
0.937" L x 0.438" W (23.80mm x 11.12mm)
0.937" (23.80mm)
Secondary:-
AC1060
CURR SENSE XFMR 60A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Force/Torque Gauges
CST306-3A
CURR SENSE XFMR 25A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CST
25 A
20kHz ~ 200kHz
Non-Invasive (Solid Core)
55 mH
2000VµS
200:1
3.75Ohm Max
0.690" L x 0.385" W (17.53mm x 9.78mm)
0.915" (23.24mm)
Secondary:-
CST306-1A
CURR SENSE XFMR 35A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
CST
35 A
20kHz ~ 200kHz
Non-Invasive (Solid Core)
3.5 mH
500VµS
50:1
340mOhm Max
0.690" L x 0.385" W (17.53mm x 9.78mm)
0.915" (23.24mm)
Secondary:-
AC1005
CURR SENSE XFMR 5A T/H
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
PC Pin
-
AC
5 A
50/60Hz
Non-Invasive (Solid Core)
-
-
1000:1
41.8Ohm
0.937" L x 0.438" W (23.80mm x 11.12mm)
0.937" (23.80mm)
Secondary:-

Current Sense Transformers

Current Sense Transformers are specialized devices that are specifically designed to detect and accurately measure the flow of current in an isolated conductor or primary winding. These transformers operate by producing an alternating current in a secondary winding that is proportional to the current being measured. The frequency range in which Current Sense Transformers operate typically spans from 2 Hz to 1 MHz. These transformers are designed to handle a wide range of current ratings, ranging from 125 mA to as high as 4000 A. There are three main types of Current Sense Transformers available: Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core). Invasive Current Sense Transformers require physical insertion into the conductor through which the current is flowing. This type of transformer provides accurate measurements but requires interruption of the circuit for installation. Non-Invasive (Solid Core) Current Sense Transformers, on the other hand, do not require any physical contact with the conductor. Instead, they are designed with a solid core around which the conductor is passed. This type of transformer offers easy installation and does not disrupt the circuit during measurement. Non-Invasive (Split Core) Current Sense Transformers are similar to the solid core type but feature a split core design. This allows the transformer to be easily opened and closed around the conductor without the need for any disconnection. It offers convenience in installation and is suitable for applications where it is impractical to interrupt the circuit. In summary, Current Sense Transformers are specialized devices used to detect and measure current flow. They generate a proportional alternating current in a secondary winding based on the current passing through an isolated conductor or primary winding. The frequency range and current ratings vary depending on the specific transformer. The three main types include Invasive, Non-Invasive (Solid Core), and Non-Invasive (Split Core), each offering different installation and measurement advantages.