CONQUER ELECTRONICS

CONQUER ELECTRONICS

Being a leading player in the fuse industry, Conquer provides an extensive selection of top-notch fuse products along with comprehensive ordering and post-sales service support. Through strategic partnerships with prominent global players, Conquer has curated a diverse range of services to facilitate the steady expansion of its clientele. With a keen emphasis on cutting-edge technological advancements, Conquer has secured numerous patents and consistently upholds the highest safety standards. Leveraging its wealth of experience and robust engineering expertise, Conquer is well-equipped to offer a wide array of products for R&D design considerations, catering to diverse customer needs across the globe.

Fuses

Results:
50
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Response Time
Approval Agency
Size / Dimension
Package / Case
Operating Temperature
Color
Fuse Type
Mounting Type
Results remaining50
Applied Filters:
CONQUER ELECTRONICS
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeVoltage Rating - ACOperating TemperaturePackage / CaseResponse TimeCurrent Rating (Amps)Approval AgencyFuse TypeVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionSeries
CQ12LI 20A 63V
FUSE BOARD MOUNT 20A 63VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
20 A
cURus
Board Mount (Cartridge Style Excluded)
63 V
100A
56
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ12LI
CRU CQ12LV 8A 125V
FUSE BOARD MOUNT 8A 125VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
8 A
cURus
Board Mount (Cartridge Style Excluded)
125 V
50A
1.728
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ12LV
CRU CQ12LV 20A 24V
FUSE BOARD MOUNT 20A 24VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
20 A
cURus
Board Mount (Cartridge Style Excluded)
24 V
150A
16
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ06LT
CQ12LI 25A 63V
FUSE BOARD MOUNT 25A 63VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
25 A
cURus
Board Mount (Cartridge Style Excluded)
63 V
100A
210
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ06LT
CQ12LI 15A 63V
FUSE BOARD MOUNT 15A 63VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
15 A
cURus
Board Mount (Cartridge Style Excluded)
63 V
100A
33
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ12LI
CRU CQ06LF 5A 63V
FUSE BOARD MOUNT 5A 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
0603 (1608 Metric)
Slow Blow
5 A
cURus
Board Mount (Cartridge Style Excluded)
63 V
35A
0.57
0.063" L x 0.031" W x 0.031" H (1.60mm x 0.80mm x 0.80mm)
CQ06LT
CRU CQ06LT 5A 63V
FUSE BOARD MOUNT 5A 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
0603 (1608 Metric)
Slow Blow
5 A
cURus
Board Mount (Cartridge Style Excluded)
63 V
35A
2.5
0.063" L x 0.031" W x 0.031" H (1.60mm x 0.80mm x 0.80mm)
CQ06LT
CRU CQ12LH 10A 24V
FUSE BOARD MOUNT 10A 24VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Slow Blow
10 A
cURus
Board Mount (Cartridge Style Excluded)
24 V
150A
12
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ06LT
SEM 1.25A 600V
FUSE BRD MNT 1.25A 600VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
600 V
-55°C ~ 125°C
2-SMD, Square End Block
-
1.25 A
cURus
Board Mount (Cartridge Style Excluded)
125 V
50A AC, 100A DC
22
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEM
SEM 2A 600V
FUSE BRD MT 2A 600VAC 125VDC SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
600 V
-55°C ~ 125°C
2-SMD, Square End Block
-
2 A
cURus
Board Mount (Cartridge Style Excluded)
125 V
50A AC, 100A DC
24
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEM
SEM 0.5A 600V
FUSE BRD MNT 500MA 600VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
600 V
-55°C ~ 125°C
2-SMD, Square End Block
-
500 mA
cURus
Board Mount (Cartridge Style Excluded)
125 V
50A AC, 100A DC
1.4
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEM
SEI 2.5A 250V (G)
FUSE BOARD MNT 2.5A 250VAC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
Slow Blow
2.5 A
TUV
Board Mount (Cartridge Style Excluded)
-
50A
20.5
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEI (G)
CQ12LI 30A 48V
FUSE BOARD MOUNT 30A 48VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
30 A
cURus
Board Mount (Cartridge Style Excluded)
48 V
150A
260
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
CQ12LI
SEI 4A 250V (G)
FUSE BOARD MOUNT 4A 250VAC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
Slow Blow
4 A
TUV
Board Mount (Cartridge Style Excluded)
-
50A
125.6
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEI (G)
SEI 1.5A 250V (G)
FUSE BOARD MNT 1.5A 250VAC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
Slow Blow
1.5 A
TUV
Board Mount (Cartridge Style Excluded)
-
50A
14.85
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEI (G)
SEH 20A 125V (G)
FUSE BRD MT 20A 125VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
125 V
-55°C ~ 125°C
2-SMD, Square End Block
-
20 A
cURus
Board Mount (Cartridge Style Excluded)
100 V
100A AC, 300A DC
18
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEH(G)
SEJ 1.25A 250V
FUSE BRD MNT 1.25A 250VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
Slow Blow
1.25 A
CCC, cURus, KC, PSE, TUV
Board Mount (Cartridge Style Excluded)
250 V
250A AC, 100A DC
4.52
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEJ
SEH 30A 125V (G)
FUSE BRD MT 30A 125VAC 100VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
125 V
-55°C ~ 125°C
2-SMD, Square End Block
-
30 A
cURus
Board Mount (Cartridge Style Excluded)
100 V
100A AC, 100A DC
101
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEH(G)
SEL 40A 250V
FUSE BOARD MOUNT 40A 250VAC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
-
40 A
cURus
Board Mount (Cartridge Style Excluded)
-
100A
1897.6
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEL
SEL 20A 250V
FUSE BRD MT 20A 250VAC 250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 V
-55°C ~ 125°C
2-SMD, Square End Block
-
20 A
cURus
Board Mount (Cartridge Style Excluded)
250 V
50A AC, 100A DC
356
0.398" L x 0.122" W x 0.122" H (10.10mm x 3.10mm x 3.10mm)
SEL

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.