SICK

SICK

SICK, a global sensor manufacturer, excels in providing cutting-edge solutions for factory automation, logistics automation, and process automation. Established in 1946 by Dr. Erwin Sick, the company is headquartered in Waldkirch im Breisgau near Freiburg, Germany. With a strong presence worldwide through over 50 subsidiaries, equity investments, and numerous agencies, SICK leads the market by offering innovative sensors and application solutions. These solutions not only ensure secure and efficient process control but also prioritize individual safety, accident prevention, and environmental protection.

Interlock Switches

Results:
178
Series
Must Operate
Termination Style
Current Rating (Amps)
Operating Temperature
Must Release
Approval Agency
Ingress Protection
Voltage Rating
Actuator Type
Circuit
Type
Holding Force
Conduit Thread Size
Voltage - Supply
Features
Results remaining178
Applied Filters:
SICK
Select
ImageProduct DetailPriceAvailabilityECAD ModelCircuitFeaturesIngress ProtectionOperating TemperatureTermination StyleApproval AgencyMust OperateMust ReleaseCurrent Rating (Amps)Actuator TypeTypeHolding ForceConduit Thread SizeVoltage - SupplySeriesVoltage Rating
I17-SA213S11
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-20°C ~ 80°C
Screw Terminal
CE, cULus
-
-
3A (AC), 2A (DC)
Panel Disconnect
Non-Locking
-
M20 x3
-
i17S
240VAC, 24VDC
STR1-SAXM0AC8S02
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
STR1-SAXM03P5
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable Leads
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
STR1-SAXM0AC8S01
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
TR4-SAM02CB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
CE, cULus
15mm
25mm
200mA (DC)
Non-Contact
RFID
-
-
24VDC
TR4
-
STR1-SAXM0AC8
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
TR4-SAM01CB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
CE, cULus
15mm
25mm
-
Non-Contact
RFID
-
-
24VDC
TR4
-
STR1-SACM0AC8
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
10mm
25mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
TR4-SAM03PB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable Leads
CE, cULus
15mm
25mm
200mA (DC)
Non-Contact
RFID
-
-
24VDC
TR4
-
I11-S213S07
INTERLOCK CUSTOM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I11-S213S08
INTERLOCK CUSTOM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I11-S213S09
INTERLOCK CUSTOM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I110-SA225
SWITCH SAFETY DPST-NC 2A 24V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-20°C ~ 80°C
Connector (M12)
CCC, CE, cULus
-
-
2A (DC)
Panel Disconnect
Non-Locking
1kgf
-
-
i110S
24VDC
TR4-SBM03PB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable Leads
CE, cULus
25mm
35mm
200mA (DC)
Non-Contact
RFID
-
-
24VDC
TR4
-
STR1-SAXM03P8
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable Leads
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
TR4-SBM01CB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
CE, cULus
25mm
35mm
200mA (DC)
Non-Contact
RFID
-
-
24VDC
TR4
-
TR4-SBM02CB
TRANSPONDER SAFETY SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
CE, cULus
25mm
35mm
200mA (DC)
Non-Contact
RFID
-
-
24VDC
TR4
-
STR1-SACM0PR8
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
10mm
25mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
STR1-SACM0PR5
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable with Connector (M12)
CE, cULus, TUV
10mm
25mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-
STR1-SAXM10P5
TRANSP -SAF SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Status Indicator
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-30°C ~ 70°C
Cable Leads
CE, cULus, TUV
14mm
28mm
100mA (DC)
Non-Contact
RFID
-
-
24VDC
STR1
-

About  Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.