Interlock Switches

Results:
3,382
Manufacturer
Series
Current Rating (Amps)
Circuit
Voltage Rating
Holding Force
Operating Temperature
Approval Agency
Conduit Thread Size
Must Operate
Features
Must Release
Voltage - Supply
Termination Style
Ingress Protection
Type
Actuator Type
Operating Position
Release Force
Operating Force
Voltage Rating - AC
Differential Travel
Mounting Type
Voltage Rating - DC
Switch Function
Overtravel
Pretravel
Results remaining3,382
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesTypeFeaturesIngress ProtectionOperating TemperatureTermination StyleCircuitActuator TypeApproval AgencyMust OperateMust ReleaseHolding ForceConduit Thread SizeCurrent Rating (Amps)Voltage - SupplyVoltage Rating
SMSAP11AB02M
SMSAP11AB02M SAFETY MAGNETIC SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3SE52320HU22
HINGE SW,SOLIDSHAFT,15SWITCHING,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3SE5
Hinge
-
IP65 - Dust Tight, Water Resistant
-
Screw Terminal
DPST-NO/NC
Shaft
CCC, CE, CSA, EAC, UKCA, UL
-
-
-
-
6A (AC), 3A (DC)
-
120VAC, 24VDC
631.1208.614
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Magnetic
-
IP67 - Dust Tight, Waterproof
-20°C ~ 70°C
Cable Leads
SPST-NO
Non-Contact
-
18mm
-
-
-
500mA (AC/DC)
-
250VAC/DC
631.0308.595
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Magnetic
-
IP65 - Dust Tight, Water Resistant
-25°C ~ 70°C
Connector
SPDT
Non-Contact
-
13mm
32mm
-
-
1A (AC/DC)
-
30VAC, 30VDC
601.6169.158
SAFETY INTERLOCK SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SK
Non-Locking
-
IP65 - Dust Tight, Water Resistant
-30°C ~ 80°C
Screw Terminal
3PST-2NC/1NO
Panel Disconnect
CCC, cCSAus, TUV
-
-
-
M20 x 1.5
1.5A (AC)
-
240VAC
631.0118.626
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MA-18
Magnetic
-
IP67 - Dust Tight, Waterproof
-5°C ~ 70°C
Cable Leads
SPST-NC
Non-Contact
-
-
-
-
-
250mA (AC/DC)
-
130VAC, 175VDC
631.0311.693
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MA-11
Magnetic
-
IP67 - Dust Tight, Waterproof
-5°C ~ 70°C
Cable Leads
SPDT
Non-Contact
UL
-
-
-
-
280mA (AC), 400mA (DC)
-
125VAC, 175VDC
601.6869.169
SAFETY INTERLOCK SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Non-Locking
-
IP65 - Dust Tight, Water Resistant
-30°C ~ 80°C
Screw Terminal
DPST-NC
Panel Disconnect
cCSAus
-
-
-
M20 x 1.5
1.5A (AC)
-
240VAC
SI-LM40MKHFD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MLK-MAG-AL
Magnet Only in MLT Aluminum hous
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Magnetic
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D4JL-3NFG-C5
SWITCH SAFETY 3PST 3A 240V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
D4JL
Solenoid Locking
-
IP67 - Dust Tight, Waterproof
-10°C ~ 55°C
Screw Terminal
3PST-2NC/1NO x 2
Panel Disconnect
CCC, CE, cULus, TUV
-
-
306kgf
1/2" NPT x2
3A (AC), 270mA (DC)
24VDC
240VAC, 250VDC
AMX5/3M
SAFETY SWITCH STAND ALONE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SI-QM100DMSG
SPRING LOCKING: STANDARD IN-LINE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SI-QM100
Solenoid Release
Manual Override
IP67 - Dust Tight, Waterproof
-30°C ~ 60°C
Screw Terminal
DPST-NO/NC x 2
Panel Disconnect
CE, CSA, UL
-
-
102kgf
M20 x2
4A (DC)
24VDC
24VDC
S400-M4M12-B
SAFETY HINGE SWITCH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
S400
Hinge
-
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
-25°C ~ 80°C
Connector
3PST-2NC/1NO
-
-
-
-
-
-
2A (AC/DC)
-
-
SMS03NC
14135222 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
3PST-2NO/1NC
Non-Contact
-
20mm
22mm
-
-
250mA (AC)
100VAC
-
SMSAP20AF03DCP
14154215 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
DPST-NO
Non-Contact
CE, UL
20mm
22mm
-
-
100mA (AC), 250mA (DC)
120VAC, 50VDC
-
SMS03+CM1A4/03MT
14127038 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Cable with Connector (M12)
DPST-NO
Non-Contact
-
20mm
22mm
-
-
250mA (AC)
100VAC
-
SMS03
14120469 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
DPST-NO
Non-Contact
-
20mm
22mm
-
-
250mA (AC)
100VAC
-
SMS02S1
14135323 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
DPST-NO/NC
Non-Contact
-
20mm
30mm
-
-
100mA (AC), 250mA (DC)
120VAC, 50VDC
-
SMS01
14117641 SAFETY MAG SEN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SMS
Magnetic
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Wire Leads
DPST-NO/NC
Non-Contact
-
10mm
15mm
-
-
250mA (AC)
100VAC
-

Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.