Interlock Switches

Results:
3,382
Manufacturer
Series
Current Rating (Amps)
Circuit
Voltage Rating
Holding Force
Operating Temperature
Approval Agency
Conduit Thread Size
Must Operate
Features
Must Release
Voltage - Supply
Termination Style
Ingress Protection
Type
Actuator Type
Operating Position
Release Force
Operating Force
Voltage Rating - AC
Differential Travel
Mounting Type
Voltage Rating - DC
Switch Function
Overtravel
Pretravel
Results remaining3,382
Select
ImageProduct DetailPriceAvailabilityECAD ModelCircuitFeaturesIngress ProtectionOperating TemperatureTermination StyleApproval AgencyMust OperateMust ReleaseCurrent Rating (Amps)Actuator TypeTypeVoltage RatingHolding ForceConduit Thread SizeVoltage - SupplySeries
XCSE7333
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Screw Terminal
CSA, UL
-
-
3A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
2kgf
1/2" NPT
-
XCSE
HS5E-A7Y001-TK2408
SWITCH INTERLOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC x 2
-
IP67 - Dust Tight, Waterproof
-25°C ~ 50°C
Cable Leads
CE, cURus, TUV
-
-
2.5A (AC/DC)
Panel Disconnect
Solenoid Locking
125VAC, 30VDC
102kgf
-
24VDC
HS5E
HS5E-A7Y003
SWITCH INTERLOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC x 2
-
IP67 - Dust Tight, Waterproof
-25°C ~ 50°C
Cable Leads
CE, cURus, TUV
-
-
2.5A (AC/DC)
Panel Disconnect
Solenoid Locking
125VAC, 30VDC
102kgf
-
24VDC
HS5E
HS5E-C4003
SWITCH INTERLOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC + DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 50°C
Cable Leads
CE, cURus, TUV
-
-
2.5A (AC/DC)
Panel Disconnect
Solenoid Release
125VAC, 30VDC
102kgf
-
24VDC
HS5E
HS5E-C4001
SWITCH INTERLOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC + DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 50°C
Cable Leads
CE, cURus, TUV
-
-
2.5A (AC/DC)
Panel Disconnect
Solenoid Release
125VAC, 30VDC
102kgf
-
24VDC
HS5E
XCSL764B3
INTERLOCK SWITCH 300 VAC 10AS XC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-1NO/2NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
-
-
-
10A (DC)
Panel Disconnect
Key Locking
24VDC
-
-
-
XCSL
XCSL764F3
INTERLOCK SWITCH 300 VAC 10AS XC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-1NO/2NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
-
-
-
10A (AC)
Panel Disconnect
Key Locking
110VAC
-
-
-
XCSL
XCSE7313
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Screw Terminal
CSA, UL
-
-
3A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
2kgf
1/2" NPT
-
XCSE
XCSE5311
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Screw Terminal
CSA, UL
-
-
3A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
2kgf
PG13.5
-
XCSE
XCSE7312
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-1NO/2NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Screw Terminal
CSA, UL
-
-
3A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
204kgf
M20 x 1.5
-
XCSE
XCSPA491
SFTYINTERLCK240VAC10ATYPEXCS MET
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
1.5A (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 125VDC
-
PG11
-
XCSPA
XCSE7331
SAFETY INTERLOCK 300VAC 5A T-XCS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Cable Leads
CSA, UL
-
-
1.5A (AC), 550mA (DC)
Panel Disconnect
Key Locking
120VAC, 125VDC
-
PG13.5
-
XCSE
XCSTE7512
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 60°C
Screw Terminal
CSA, UL
-
-
3A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
-
M16 x 1.5
-
XCST
XCSDMP7012
CODED MAGNETIC SWITCH, TELEMECAN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 85°C
Cable Leads
CSA, UL
8mm
20mm
100mA (DC)
Non-Contact
Magnetic
24VDC
-
-
-
XCSDMP
XCSPA793
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
6A (AC), 550mA (DC)
Panel Disconnect
Non-Locking
120VAC, 125VDC
1kgf
1/2" NPT
-
XCSPA
XCSLF3535412
METAL INTLK W/O POWER, 24 VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP66 - Dust Tight, Waterproof
-25°C ~ 60°C
Cable Leads
CSA, TUV, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 24VDC
-
M20 x 1.5
-
XCSLF
XCSPL761
SAFETY INTERLOCK 240VAC 10A T-XC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
BG, CSA, UL
-
-
-
Arm Lever
Non-Locking
-
-
PG11
-
XCSPL
XCSMP80L2
SAFETY INTERLOCK 300VAC 2.5A T-X
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Cable Leads
CSA, cUL, UL
-
-
1.5A (AC), 550mA (DC)
Panel Disconnect
Key Locking
120VAC, 125VDC
-
-
-
XCSMP
XCSLF3737412
METAL INTLK W/O POWER, 24 VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP66 - Dust Tight, Waterproof
-25°C ~ 60°C
Cable Leads
CSA, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 24VDC
-
M20 x 1.5
-
XCSLF
XCSLF3535533
METAL INTER, LOCK W/ POWER, 120
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 60°C
Cable Leads
CSA, TUV, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 24VDC
-
1/2" NPT
-
XCSLF

Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.