Interlock Switches

Results:
3,313
Manufacturer
Series
Current Rating (Amps)
Circuit
Voltage Rating
Holding Force
Operating Temperature
Approval Agency
Conduit Thread Size
Must Operate
Features
Must Release
Voltage - Supply
Termination Style
Ingress Protection
Type
Actuator Type
Operating Position
Release Force
Operating Force
Voltage Rating - AC
Differential Travel
Mounting Type
Voltage Rating - DC
Switch Function
Overtravel
Pretravel
Results remaining3,313
Select
ImageProduct DetailPriceAvailabilityECAD ModelCircuitFeaturesIngress ProtectionOperating TemperatureTermination StyleApproval AgencyMust OperateMust ReleaseCurrent Rating (Amps)Actuator TypeTypeVoltage RatingHolding ForceConduit Thread SizeVoltage - SupplySeries
XCSTE7313
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 60°C
Screw Terminal
CSA, UL
-
-
3A (AC)
Panel Disconnect
Solenoid Locking
120VAC, 125VDC
51kgf
1/2" NPT
-
XCSTE
HS1C-L244R-G
SOLENOID SFTY SWTCH 2NC/2NC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
*
HS1E-8C-TK2267
HS1E FOR TOYOTA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
*
HS5E-A44L03-G
SWITCH INTERLOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC x 2
Status Indicator, Manual Override
IP67 - Dust Tight, Waterproof
-25°C ~ 50°C
Cable Leads
CCC, CE, cURus, TUV
-
-
2.5A (AC/DC)
Panel Disconnect
Solenoid Release
125VAC, 30VDC
143kgf
-
24VDC
HS5E
XCSA503
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
6A (AC), 550mA (DC)
Panel Disconnect
Non-Locking
120VAC, 125VDC
-
-
-
XCSA
XCSDMP7005
CODED MAGNETIC SWITCH, TELEMECAN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-1NO/2NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 85°C
Cable Leads
CSA, UL
8mm
20mm
100mA (DC)
Non-Contact
Magnetic
24VDC
-
-
-
XCSDMP
XCSLE2727313
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 60°C
Screw Terminal
CSA, TUV, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
240VAC, 24VDC
143kgf
1/2" NPT
-
XCSLE
XCSC703
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
6A (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 250VDC
-
1/2" NPT
-
XCSC
XCSB803
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
6A (AC), 550mA (DC)
Panel Disconnect
Solenoid Locking
240VAC, 250VDC
-
1/2" NPT
-
XCSB
XCSB703
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
CSA, UL
-
-
6A (AC), 550mA (DC)
Panel Disconnect
Solenoid Release
120VAC, 125VDC
2kgf
1/2" NPT
-
XCSB
XCSPR763
SAFETY INTERLOCK 240VAC 10A T-XC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
BG, CSA, UL
-
-
-
Shaft
Non-Locking
-
-
1/2" NPT
-
Telemecanique XCS
XCSL784B3
SAFETY SWITCH, TELEMECANIQUE SAF
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
Screw Terminal
-
-
-
-
Panel Disconnect
Non-Locking
-
-
-
-
XCSL
XCSDMR7902
CODED MAGNETIC SWITCH, TELEMECAN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 85°C
Cable Leads
CSA, UL
8mm
20mm
100mA (DC)
-
Magnetic
24VDC
-
-
-
XCSDMR
XCSE5313
SAFETY INTERLOCK 300VAC 5A T-XCS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 40°C
Cable Leads
CSA, UL
-
-
1.5A (AC), 550mA (DC)
Panel Disconnect
Key Locking
120VAC, 125VDC
-
1/2" NPT
-
XCSE
XCSDMP59110
SAFETY INTER, MAG, RECT, 10 M CA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NO/NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 85°C
Cable Leads
CSA, UL
8mm
20mm
100mA (DC)
Non-Contact
Magnetic
100VDC
-
-
-
XCSDMP
XCSL766B2
INTERLOCK SWITCH 300VAC 10AS XCS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
Screw Terminal
-
-
-
-
Panel Disconnect
Key Locking
-
-
-
-
XCSL
XCSLF353531M3
METAL INTLK W/ POWR, 24 VAC/DC,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NO/1NC
-
IP65 - Dust Tight, Water Resistant
-25°C ~ 60°C
Connector
CSA, TUV, UL
-
-
1.5A (AC), 220mA (DC)
Panel Disconnect
Key Locking
24VAC, 24VDC
-
-
-
XCSLF
XCSLF3838312
METAL INTER, LOCK W/O POWER, 24
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-NC
-
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
-25°C ~ 60°C
Cable Leads
CSA, TUV, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 24VDC
-
M20 x 1.5
-
XCSLF
XCSLF3737533
SAFETY INTERLOCK, METAL, LOCKING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3PST-2NC/1NO
-
IP66 - Dust Tight, Waterproof
-25°C ~ 60°C
Cable Leads
CSA, TUV, UL
-
-
750mA (AC), 550mA (DC)
Panel Disconnect
Key Locking
240VAC, 24VDC
-
1/2" NPT
-
XCSLF
XCSPL771
SAFETY INTERLOCK 240VAC 10A T-XC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DPST-NC
-
IP67 - Dust Tight, Waterproof
-25°C ~ 70°C
Screw Terminal
BG, CSA, UL
-
-
-
Arm Lever
Non-Locking
-
-
PG11
-
XCSPL

Interlock Switches

Interlock switches, also known as safety interlock switches, serve as indispensable components in ensuring the safe operation of machinery and equipment by preventing them from operating in hazardous or unsafe conditions. The primary purpose of interlock switches is to establish a reliable means of controlling access to machinery and equipment, ensuring that certain conditions are met before the machine can be activated. These switches are designed to create an interlocking mechanism that effectively safeguards operators and surrounding personnel from potential harm. Interlock switches are strategically placed at critical access points or areas where hazardous conditions may arise. These access points can include doors, gates, panels, or any other openings that provide entry to the machinery. By incorporating interlock switches at these points, the machine's operation is contingent upon the proper positioning and engagement of these switches. To activate the interlock switch, a specific action must be performed, such as closing a door or securing a gate. This action ensures that the machine is in a safe state, with all necessary guards or protective measures in place, before it can be enabled. In the event that the interlock switch is not properly engaged or the access point is compromised, the switch sends a signal to the control system, preventing the machine from starting or stopping its operation. This mechanism effectively prevents any potentially dangerous scenarios, such as accidental activation or exposure to moving parts, from occurring. Interlock switches are designed with robust construction and reliability to withstand the demanding industrial environments in which they are used. They are engineered to provide fail-safe operation, ensuring that the machine remains in a safe state until all hazardous conditions are rectified. Moreover, interlock switches often incorporate features that allow for lock-out, tag-out procedures, further enhancing safety protocols. These procedures involve isolating the energy source and placing a lock or tag on the switch to prevent unauthorized or accidental activation during maintenance or repair work. In summary, interlock switches play a critical role in maintaining the safety of machinery and equipment by preventing operation in unsafe conditions. By incorporating these switches at access points, the machine's activation is contingent upon proper engagement, ensuring that all necessary safeguards are in place. The fail-safe operation and lock-out, tag-out features of interlock switches contribute to creating a secure working environment and minimizing the risk of accidents or injuries.