Isolation Transformers and Autotransformers, Step Up, Step Down

Results:
587
Manufacturer
Series
Power - Max
2nd Connector
Voltage - Primary
Voltage - Secondary
1st Connector
Power (Watts)
Type
Specifications
For Use With/Related Products
Hardware Type
Results remaining587
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesTypeVoltage - Primary1st Connector2nd ConnectorPower - Max
TP-VC277-220VAC
277VAC TO 220VAC VOLTAGE CONVERT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
277V
Wire Leads
-
400VA
175B
TRANSFORMER 230 TO 115VAC 200VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175
Autotransformer (Non-Isolated)
230V
NEMA 5-15P
NEMA 5-15R
298D
TRANSFM ISOL 115 TO 230VCT 500VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
298
Isolation
115V
NEMA 5-15P
-
289F
TRANSFORMR ISOL 230-115VAC 1KVA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
289
Isolation
230V
NEMA 5-15P
-
CV1202300
TRANSFORMER - CONSTANT VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
CV
-
-
-
-
175D
TRANSFORMER 230 TO 115VAC 500VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175
Autotransformer (Non-Isolated)
230V
NEMA 5-15P
NEMA 5-15R
175F
TRANSFORMER 230 TO 115VAC 1KVA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175
Autotransformer (Non-Isolated)
230V
NEMA 5-15P
NEMA 5-15R
CV240300
TRANSFORMER - CONSTANT VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
CV
-
-
-
-
175C
TRANSFORMER 230 TO 115VAC 300VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175
Autotransformer (Non-Isolated)
230V
NEMA 5-15P
NEMA 5-15R
289D
TRANSFORMR ISOL 230-115VAC 500VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
289
Isolation
230V
NEMA 5-15P
-
175E
TRANSFORMER 230 TO 115VAC 750VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175
Autotransformer (Non-Isolated)
230V
NEMA 5-15P
NEMA 5-15R
179E
TRANSFORMR ISOL 115 TO 95V 750VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
179
Isolation
115V
NEMA 5-15P
NEMA 5-15R (2)
289E
TRANSFORMR ISOL 230-115VAC 750VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
289
Isolation
230V
NEMA 5-15P
-
CV2402300
TRANSFORMER - CONSTANT VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
CV
-
-
-
-
CV240600
TRANSFORMER - CONSTANT VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
CV
-
-
-
-
175E-EU
TRANSF AUTO 230-115V 750VA EUROP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
175EU
Autotransformer (Non-Isolated)
230V
CEE 7/4
NEMA 5-15R
CV1201800
REGULATOR 1800VAC 6 OUTLETS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
CV
Isolation
120V
NEMA 5-15P
NEMA 5-15R (6)
1800VA
ICT-H-C-12
INDUSTRIAL CONTROL TRANSFORMER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
ICT-S-B-16
INDUSTRIAL CONTROL TRANSFORMER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
SU-10
XFRMR ISO PWR 10KVA 20.5/41A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SU
Isolation
104V, 110V, 120V, 208V, 220V, 230V, 240V
Screw Terminal
Screw Terminal
10000VA

About  Isolation Transformers and Autotransformers, Step Up, Step Down

The products within this category are intended to be used in conjunction with AC utility power for various safety or functional purposes. Two common types of transformers in this family are isolation transformers and autotransformers. Isolation transformers are specifically designed to transfer electrical power from one circuit to another without establishing a direct electrical connection. They provide galvanic isolation, which means they prevent the flow of electric current between the input and output circuits. Isolation transformers are frequently utilized in repair or product development environments where the mitigation of shock hazards is crucial. By isolating the circuits, these transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. On the other hand, autotransformers are used for voltage scaling purposes. They can increase or decrease the voltage of an available power source to meet specific functional requirements. Unlike isolation transformers, autotransformers do not provide galvanic isolation between the input and output circuits. Therefore, they are employed when electrical isolation is not necessary. Autotransformers are commonly used in scenarios where voltage conversion is needed, such as stepping up or stepping down the voltage for specific equipment or devices. In summary, products within this category serve different purposes in relation to AC utility power. Isolation transformers are utilized to transfer electrical power without establishing a galvanic connection, ensuring safety by mitigating shock hazards. Autotransformers, on the other hand, are used to scale the voltage of an available source to meet functional requirements when isolation between input and output circuits is unnecessary.