Monitor - Relay Output

Results:
1,159
Manufacturer
Series
Trip Range
Voltage - Supply
Delay Time
Contact Rating @ Voltage
Type
Circuit
Trip Status
Mounting Type
Output Type
Termination Style
Number of Outputs and Type
Number of Inputs and Type
For Use With/Related Products
Features
Results remaining1,159
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeOutput TypeCircuitContact Rating @ VoltageVoltage - Supply
ECSH40AD
RELAY CUR SENSE 120VAC 0.5-5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
ECS
Current Sensing AC
Energized High
0.5 ~ 5A AC
0.15 Sec ~ 7 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
120VAC
RM35BA10
HARMONY, MODULAR 3-PHASE AND 1-P
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Phase Sequence
Energized High/Low
1 ~ 10A AC
Fixed, 0.3 Sec; 0.1 Sec ~ 60 Sec
Relay
SPDT (1 Form C)
5A @ 250VAC/250VDC
208 ~ 480VAC
RM35LV14MW
HARMONY, MODULAR LIQUID LEVEL CO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Liquid Level Monitoring
Energized High/Low
-
0.1 Sec ~ 5 Sec
Relay
SPDT (1 Form C)
5A @ 250VAC/250VDC
24 ~ 240VAC/DC
RM17UAS15
HARMONY, MODULAR 1-PHASE VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Voltage Sensing AC/DC
Energized High/Low
65 ~ 260V AC
0.1 Sec ~ 10 Sec
Relay
SPDT (1 Form C)
5A @ 250VAC/250VDC
110 ~ 240VAC
RM22TA33
HARMONY, MODULAR 3-PHASE SUPPLY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Voltage Asymmetry, Phase Loss, Phase Sequence
Energized High/Low
380 ~ 480V AC
0.1 Sec ~ 30 Sec
Relay
DPDT (2 Form C)
8A @ 250VAC
380 ~ 480VAC
RM22TR33
HARMONY, MODULAR 3-PHASE VOLTAGE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Phase Loss, Phase Sequence, Voltage Sensing AC
Energized High/Low
380 ~ 480V AC
0.1 Sec ~ 30 Sec
Relay
DPDT (2 Form C)
8A @ 250VAC
380 ~ 480VAC
RM22UA33MR
VOLT MON RELAY, 24-240VAC IN,15-
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Voltage Sensing AC/DC
Energized High/Low
15 ~ 500V AC/DC
0.1 Sec ~ 30 Sec
Relay
DPDT (2 Form C)
8A @ 250VAC
24 ~ 240VAC/DC
RM22UA22MR
HARMONY, MODULAR 1-PHASE OVERVOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Voltage Sensing AC/DC
Energized High/Low
1 ~ 100V AC/DC
No Delay
Relay
DPDT (2 Form C)
8A @ 250VAC
24 ~ 240VAC/DC
RM22TG20
PHASE CTRL RELAY, 208-480VAC IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
Harmony
Voltage Asymmetry, Phase Loss, Phase Sequence
Energized High/Low
200 ~ 240V AC
0.1 Sec ~ 30 Sec
Relay
DPDT (2 Form C)
8A @ 250VAC
208 ~ 480VAC
ECSH41BC
RELAY CUR SENSE 120VAC 2-20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
ECS
Current Sensing AC
Energized High
2 ~ 20A AC
0.5 Sec ~ 50 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
120VAC
460-B
3-PHASE VOLT MON/ 190-480V/AD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
460
Voltage Asymmetry, Voltage Sensing AC, Phase Loss
Energized High/Low
190 ~ 480V AC
1 Sec ~ 30 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
190 ~ 480VAC
ECSH31F.08D
RELAY CUR SENSE 24VDC 2-20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
ECS
Current Sensing AC
Energized High
2 ~ 20A AC
Fixed, 0.08 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
24VDC
PLM6502
3 PHASE LINE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
PLM
Voltage Asymmetry, Voltage Sensing AC, Phase Loss
Energized Low
200 ~ 240V AC
Fixed, 2 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
240VAC
ECS2HBC
RELAY CUR SENSE 24VAC 5-50A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
ECS
Current Sensing AC
Energized High/Low
5 ~ 50A AC
0.5 Sec ~ 50 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
24VAC
ECS61BC
RELAY CUR SENSE 230VAC 2-20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
ECS
Current Sensing AC
Energized High/Low
2 ~ 20A AC
0.5 Sec ~ 50 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
230VAC
Q50F
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Q-50, HARTMAN
Current Sensing DC
-
-
-
Relay
SPDT (1 Form C)
0.25A @ 28VDC
28VDC
Q50A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Q-50, HARTMAN
Current Sensing DC
-
-
-
Relay
SPST-NO (1 Form A)
0.25A @ 28VDC
28VDC
LSRX-OEM
LSRX 10 PACK
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRX
Current Sensing AC
Energized High
5 ~ 200A AC
No Delay
Relay
SPST-NO (1 Form A)
5A @ 240VAC
-
SDV-FH7T AC200/220V
VOLTAGE SENSOR RELAY SHUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
SDV
Voltage Sensing AC/DC
-
10 ~ 300V AC/DC
No Delay
Relay
SPDT (1 Form C)
5A @ 220VAC
200 ~ 220VAC
460-200-SP
1-PHASE VOLTAGE MONITOR/ 190-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
460-XXX-SP
Voltage Sensing AC
Energized High/Low
190 ~ 240V AC
Fixed, 4 Sec
Relay
SPDT (1 Form C)
10A @ 240VAC
190 ~ 240VAC

Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.