Monitor - Relay Output

Results:
1,159
Manufacturer
Series
Trip Range
Voltage - Supply
Delay Time
Contact Rating @ Voltage
Type
Circuit
Trip Status
Mounting Type
Output Type
Termination Style
Number of Outputs and Type
Number of Inputs and Type
For Use With/Related Products
Features
Results remaining1,159
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
K8DT-VS3CD
VOLTAGE RELAY 20-600 V PUSH IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8DT
Voltage Sensing AC/DC
-
20 ~ 600V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
84873012
CONTROL RELAY PHASE 3X400VAC DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
FW
Phase Loss, Phase Sequence, Voltage Sensing AC
-
320 ~ 460V AC
0.2 Sec ~ 10 Sec
400VAC
Relay
DPDT (2 Form C)
8A @ 250VAC
84873011
CONTROL RELAY PHASE 3X380VAC DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
FW
Phase Loss, Phase Sequence, Voltage Sensing AC
Energized High/Low
310 ~ 337V AC
0.2 Sec ~ 10 Sec
304 ~ 337VAC
Relay
DPDT (2 Form C)
8A @ 250VAC
84872305
CONTROL RELAY VOLT 230VAC .2-60V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
HDU
Voltage Sensing AC/DC
Energized High/Low
0.2 ~ 60V AC/DC
0.1 Sec ~ 3 Sec
230VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
84872057
CONTROL RELAY VOLTG 65-260VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
EUSF
Voltage Sensing AC/DC
Energized High/Low
65 ~ 260V AC/DC
0.1 Sec ~ 3 Sec
90 ~ 270VAC/DC
Relay
SPDT (1 Form C)
8A @ 250VAC
84872040
CONTROL RELAY VOLTAGE 12VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
EUS
Voltage Sensing DC
Energized High/Low
9.6 ~ 15.6V DC
0.1 Sec ~ 3 Sec
12VDC
Relay
SPDT (1 Form C)
8A @ 250VAC
CR7310-EH-120-.11-X-CD-ELR-I
REL AC GROUND FAULT SENS 120VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR7310
Ground Fault Sensing AC
Energized High
0.1 ~ 1.0A AC
No Delay
120VAC
Relay
SPDT (1 Form C)
20A @ 240VAC
201-200-DPDT
3-PH 11-PIN PLUG-IN VM / 90 -
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
201-XXX-DPDT
Voltage Sensing AC
Energized Low
190 ~ 240V AC
Fixed, 2 Sec, 4 Sec
190 ~ 240VAC
Relay
DPDT (2 Form C)
10A @ 240VAC
111-INSIDER-P
1-PHASE PUMPSAVERPLUS/115V/FOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
-
Voltage Sensing AC
Energized High/Low
95 ~ 132.5V AC
No Delay
-
Solid State
-
-
K8DT-VS3TD
VOLTGE TRANSNPN 20-600V PSH IN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8DT
Voltage Sensing AC/DC
-
20 ~ 600V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Solid State
NPN
-
CR5395-EH-ACV-110-X-CD-ELR-I
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
No Delay
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
K8AK-AW2 100-240VAC
OVR/UNDR RELAY 0.1 TO 5 A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
0.1 ~ 8A AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
50R4002
1-PHASE VOLTAGE MONITOR/ 380-4
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
50R
Voltage Sensing AC
Energized Low
380 ~ 480V AC
2 Sec ~ 300 Sec
380 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
K8DT-PZ2CN
3-PHSE SQNCE&PHSELSS TNS PSHIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8DT
Phase Loss, Phase Sequence
-
-
0.1 Sec ~ 30 Sec
380 ~ 480VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AW1 24VAC/DC
OVR/UNDR RELAY 2 TO 500 MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
2 ~ 500mA AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
UOA-110-DLA
VOLTAGE MONITORING RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
UOA
Voltage Sensing DC
Energized High/Low
92 ~ 130V DC
0.05 Sec ~ 0.5 Sec
110VDC
Relay
DPDT (2 Form C)
5A @ 240VAC
K8AK-AS1 24VAC/DC
CURRENT RELAY 2 TO 500MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
2 ~ 500mA AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
84873220
RELAY MONITOR 3PHASE 220-480V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
C-Lynx
Phase Loss, Phase Sequence
Energized High
200 ~ 484V AC
0.1 Sec ~ 3 Sec
230 ~ 400VAC
Relay
DPDT (2 Form C)
8A @ 250VAC
K8DS-PH1 200/480VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8DS
Phase Loss, Phase Sequence
-
-
No Delay
200 ~ 480VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
PLMU11
3 PHASE LINE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Socketable
PLMU11
Voltage Sensing AC
-
200 ~ 480V AC
0.25 Sec ~ 30 Sec
200 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 240VAC

Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.