Power Line Filter Modules

Results:
14,159
Manufacturer
Series
Inductance
Current
Approval Agency
Termination Style
Voltage - Rated AC
Operating Temperature
Voltage - Rated DC
Voltage - Rated AC (Phase to Ground/Neutral)
Voltage - Rated AC (Phase to Phase)
Frequency - Operating
Applications
Mounting Type
Filter Type
Configuration
Ingress Protection
Current Rating (Amps)
Voltage Rating - AC
Features
Illumination Type, Color
Actuator Marking
Actuator Type
Panel Cutout Dimensions
Circuit
Illumination Voltage (Nominal)
Type
Voltage Rating - DC
Switch Function
Color - Actuator/Cap
Results remaining14,159
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeApplicationsOperating TemperatureCurrentInductanceApproval AgencySeriesFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACFrequency - OperatingTermination StyleVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)
3-130-966
5124 CONNECTOR FILTER C14 15A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
15 A
600µH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-938
5124 CONNECTOR FILTER C14 6A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
6 A
4.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-970
5124 CONNECTOR FILTER C14 6A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
6 A
4.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-937
5124 CONNECTOR FILTER C14 4A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
4 A
8.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-972
5124 CONNECTOR FILTER C14 15A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
15 A
600µH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-967
5124 CONNECTOR FILTER C14 1A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
1 A
89mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-969
5124 CONNECTOR FILTER C14 4A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
4 A
8.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-936
5124 CONNECTOR FILTER C14 2A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
2 A
33mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-968
5124 CONNECTOR FILTER C14 2A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
2 A
33mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-940
5124 CONNECTOR FILTER C14 15A M5
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
Medical
-25°C ~ 85°C
15 A
600µH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
10DKPS4(D)
2-STAGE PLASTIC CASE FILTER 10A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-
10 A
1.7mH
cURus, ENEC
DKP
Single Phase
Single Stage
-
250V
50/60Hz
Terminal Block
-
-
3-130-964
5124 CONNECTOR FILTER C14 6A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
6 A
4.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-963
5124 CONNECTOR FILTER C14 4A STD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
4 A
8.7mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
3-130-965
5124 CONNECTOR FILTER C14 10A ST
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Panel Mount
General Purpose
-25°C ~ 85°C
10 A
1.5mH
CQC, cURus, ENEC
5124
Single Phase
Single Stage
-
250V
50/60Hz
IEC 320-C14, Quick Connect
-
-
FMBB-33MF-3030
LINE FILTER 125V/250VAC 30A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
-40°C ~ 100°C
30 A
-
cURus, ENEC, VDE
FMBB EP
Single Phase
Two Stage
-
125V, 250V
50/60Hz
Threaded Post (M4)
-
-
FMBB-33MC-1240
LINE FILTER 125V/250VAC 12A CHAS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
Medical
-40°C ~ 100°C
12 A
-
cURus, ENEC, VDE
FMBB EP
Single Phase
Two Stage
-
125V, 250V
50/60Hz
Quick Connect
-
-
16DKPS4
2-STAGE PLASTIC CASE FILTER 16A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-
16 A
500µH
cURus, ENEC
DKP
Single Phase
Single Stage
-
250V
50/60Hz
Terminal Block
-
-
20DKPS4
2-STAGE PLASTIC CASE FILTER 20A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-
20 A
500µH
cURus, ENEC
DKP
Single Phase
Single Stage
-
250V
50/60Hz
Terminal Block
-
-
04DRPS4
2-STAGE PLASTIC CASE FILTER 4A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-
4 A
6.4mH
cURus, ENEC
DRP
Single Phase
Two Stage
-
250V
50/60Hz
Terminal Block
-
-
06DKPS4E
2-STAGE PLASTIC CASE FILTER 6A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
General Purpose
-
6 A
26mH
cURus, ENEC
DKP
Single Phase
Single Stage
-
250V
50/60Hz
Terminal Block
-
-

Power Line Filter Modules

Power line filter modules are essential components used to prevent the flow of current through power supply conductors at frequencies that deviate from the intended supply frequency. These modularized passive component assemblies are particularly useful in conjunction with AC utility power sources. They serve two main purposes: mitigating interference from external sources and suppressing potential interference generated by connected devices. The primary function of a power line filter module is to attenuate electrical noise and electromagnetic interference (EMI) that can disrupt the normal operation of electrical equipment. These filters are designed to allow the desired power frequency to pass through while effectively blocking or attenuating unwanted frequencies. By doing so, they ensure that only clean and stable power is supplied to connected devices. When it comes to external interference, power line filter modules act as a barrier, preventing noise and EMI from entering the power supply system. This interference can originate from sources such as radio signals, nearby electrical equipment, or other sources of electrical noise. The filter module's design includes various passive components, such as capacitors and inductors, which work together to create a path of high impedance for unwanted frequencies, effectively filtering them out. Moreover, power line filter modules also suppress potential interference that might be generated by the connected devices themselves. Some electrical devices, especially those with switching power supplies or motors, can introduce noise back into the power supply system. The filter modules help mitigate this issue by providing a low-impedance path for the unwanted frequencies generated by the device, thereby preventing them from propagating further into the power supply network and affecting other connected equipment. By incorporating power line filter modules into a power supply system, both external and internal sources of interference can be effectively controlled. This ensures the reliable operation of sensitive equipment and helps maintain the overall integrity of the power distribution network. In summary, power line filter modules are modularized passive component assemblies that play a crucial role in inhibiting current flow through power supply conductors at frequencies outside the intended supply range. They are utilized to mitigate interference from external sources and suppress potential interference caused by connected devices. By selectively filtering out unwanted frequencies, these modules contribute to the stable and reliable operation of electrical equipment.