TELE Controls, Inc. is dedicated to meeting and surpassing the domestic sourcing requirements of original equipment manufacturers (OEMs), resellers, and distributors across North America. Since 1963, TELE has been safeguarding, monitoring, and automating systems and equipment for diverse industries. Quality and dependable protective equipment doesn't have to come with a hefty price tag. Leveraging our advanced automated production facility in Vienna, Austria, we provide unmatched technology, quality, and reliability at a competitive price point. Our Virginia-based team ensures that all your needs are catered to across the nation.

Protection Relays & Systems

Results:
8
Series
Voltage - Supply
Function
Trip Range
Delay Time
Operating Temperature
Features
Termination Style
Mounting Type
Results remaining8
Applied Filters:
TELE Controls, Inc.
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesOperating TemperatureMounting TypeVoltage - SupplyTermination StyleDelay TimeFeaturesTrip RangeFunction
G2JM5AL20 24-240V AC/DC
3-PH OVERLOAD RELAY, CURRENT, 5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
24 ~ 240VAC/DC
Screw Terminal
0.1 ~ 10s
Automatic Reset
5 ~ 6A
Ground Fault , Overcurrent, Undercurrent
G2CU400V10AL10
POWER FACTOR MONITOR PUMPSAVER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
12 ~ 400VAC, 24VDC
Screw Terminal
0.1 ~ 40s
Automatic Reset
40 ~ 415VAC
Ground Fault , Underload
G2PU690VS20
180-690V PHASE LOSS MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
GAMMA
-25°C ~ 70°C
DIN Rail
177 ~ 794VAC
Screw Terminal
0.1 ~ 10s
Automatic Reset
180 ~ 690VAC
Phase Imbalance, Phase Loss, Phase Sequence, Overvoltage, Undervoltage
G2CM400V10AL20
POWER FACTOR MONITOR UNDERLOAD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
12 ~ 400VAC
Screw Terminal
0.1 ~ 40s
Automatic Reset
40 ~ 415VAC
Ground Fault , Overload, Underload
NA003-M64
GRID PROTECT, VOLTAGE FREQ
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
DIN Rail
110 ~ 230VAC, 24VDC
Screw Terminal
0 ~ 600s
-
0 ~ 560VAC, 40 ~ 65Hz
Overfrequency, Overvoltage, Underfrequency, Undervoltage
G4CM690V16ATL20
POWER FACTOR MONITOR RELAY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
12 ~ 500VAC
Screw Terminal
1 ~ 50s
Automatic Reset
85 ~ 690VAC
Ground Fault, Overtemperature
E1PF480Y/277VSY01
PHASE MONITOR RELAY 3-PH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ENYA
-25°C ~ 55°C
DIN Rail
208/120 ~ 480/277VAC
Screw Terminal
0.1s
Automatic Reset
G4BM480V12ADTL20 24-240V AC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 40°C
DIN Rail
24 ~ 240VAC/DC
Screw Terminal
Automatic Reset

About  Protection Relays & Systems

Protection relays are essential components of industrial systems designed to detect and respond to abnormal operating conditions, preventing damage to equipment and ensuring the safety of personnel. These relays constantly monitor the system for any deviations from normal operating parameters, triggering an alert or disconnecting the offending device from the network to prevent potential hazards. Arc-Flash Detection: Arc-flash detection relays are used to monitor electrical activity and detect dangerous arcing faults in electrical systems. These relays can quickly identify arc-flash events and trigger a system shutdown to prevent further damage. Temperature Monitoring: Temperature monitoring relays are employed to detect overheating conditions in electrical equipment, such as motors and transformers. These relays can sense temperature changes in real-time and initiate corrective measures before the equipment is damaged. Ground Fault Detection: Ground fault detection relays are utilized to detect faults in the grounding system of electrical equipment, preventing electrical shocks and minimizing damage to the equipment. Over-Current Protection: Over-current protection relays are designed to detect excessive current flow in electrical systems, such as short circuits or overloads. These devices can quickly disconnect the affected circuit, limiting the damage and preventing disruption to the rest of the system. Over-Voltage Protection: Over-voltage protection relays are used to detect and protect against voltage surges or spikes in electrical systems, preventing damage to sensitive equipment and reducing the risk of electrical fires. Reverse Power Flow Protection: Reverse power flow protection relays are utilized in power generation systems to detect and prevent the reverse flow of power into the generator, protecting against potential damage and improving system stability. Over-Frequency and Under-Frequency Protection: Over-frequency and under-frequency protection relays are employed to detect deviations from normal frequency levels in electrical systems, such as those caused by load shedding or generator failure. These relays can initiate corrective measures to restore the system to its normal operating frequency. Phase Loss, Sequence, or Imbalance Protection: Phase loss, sequence, or imbalance protection relays are used to detect and prevent electrical system faults caused by phase loss, sequence deviation, or voltage imbalances, protecting against equipment damage and reducing the risk of electrical hazards. In summary, protection relays serve as critical components of industrial systems designed to detect and respond to abnormal operating conditions, preventing damage to equipment and ensuring the safety of personnel. These relays employ a variety of detection functions, including arc-flash, temperature monitoring, ground fault, over-current, over-voltage, reverse power flow, over-frequency, under-frequency, and phase loss, sequence, or imbalance protection. By constantly monitoring the system for deviations from normal operating parameters, these relays facilitate the efficient and reliable operation of industrial systems, ultimately supporting the performance and functionality of a wide array of industrial machinery and equipment.