MINI MCR Series, Signal Conditioners and Isolators

Results:
68
Manufacturer
Series
Input Range (Current, Voltage)
Output Range
Voltage - Supply
Operating Temperature
Input Type
Isolation
Output Type
Type
Input Range (Additional)
Termination Style
Mounting Type
Features
Results remaining68
Applied Filters:
MINI MCR
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesFeaturesOperating TemperatureOutput TypeMounting TypeVoltage - SupplyTermination StyleTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output RangeIsolation
2813554
3-WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Voltage
DIN Rail
24VDC
Spring Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
1500V (Test)
2813570
MCR 3-WAY ISOLATING AMPLIFIER FO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
1500V (Test)
2901995
SINGLE-CHANNEL INPUT LOOP-POWERE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
Loop Powered
Spring Terminal
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
3000V (Test)
2902000
MINI MCR-2-I0-U
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
-
2902003
MINI MCR-2-I4-U-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current
4 ~ 20mA
-
0 ~ 10V
-
2902001
MINI MCR-2-I0-U-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
-
2902022
MINI MCR-2-U-I0
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
-
2901999
MINI MCR-2-I-I-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
24VDC
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
-
2902023
MINI MCR-2-U-I0-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
-
2902030
MINI MCR-2-U-I4-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
4 ~ 20mA
-
2901997
TWO-CHANNEL INPUT LOOP-POWERED 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
Loop Powered
Spring Terminal
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
3000V (Test)
2901996
TWO-CHANNEL INPUT LOOP-POWERED 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current
DIN Rail
Loop Powered
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
3000V (Test)
2902017
MINI MCR-2-POT-UI-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current, Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Resistance
-
0.1 ~ 100kOhm
0 ~ 20mA, 0 ~ 10V (Configurable)
-
2813541
3-WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
1500V (Test)
2813512
MCR 3-WAY ISOLATING AMPLIFIER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
1500V (Test)
2902028
MINI MCR-2-UNI-UI-UIRO-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-40°C ~ 70°C
Current, Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
0 ~ 20mA, 0 ~ 10V (Configurable)
-
2902829
REPEATER POWER SUPPLY
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-25°C ~ 70°C
Current
DIN Rail
Loop Powered
Screw Terminal
Signal Conditioner
Current
±40mA, ±30V (Configurable)
-
4 ~ 20mA (Configurable)
1500V (Test)
2864176
4-WAY SIGNAL DUPLICATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 60°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner Multiplier
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
-
0 ~ 20mA (Configurable)
1500V (Test)
2902061
OUTPUT LOOP-POWERED 2-WAY ISOLAT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-25°C ~ 65°C
Current
DIN Rail
Loop Powered
-
Signal Conditioner
Current
4 ~ 20mA, ±20V (Configurable)
-
4 ~ 20mA (Configurable)
3000V (Test)
2810780
3-WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Current, Voltage
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
±3V (Configurable)
-
0 ~ 20mA, 0 ~ 10V (Configurable)
1500V (Test)

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.