Dataforth

Dataforth

Dataforth, a global leader in the industry, specializes in developing cutting-edge solutions for signal conditioning, data acquisition, and data communication tailored to meet the evolving needs of the factory automation sector. With a commitment to innovation, Dataforth consistently expands its product portfolio with high-quality solutions designed for industrial applications, ensuring sustained growth and customer satisfaction.

Signal Conditioners and Isolators

Results:
424
Series
Input Range (Current, Voltage)
Input Range (Additional)
Output Range
Input Type
Output Type
Voltage - Supply
Operating Temperature
Termination Style
Mounting Type
Type
Isolation
Features
Results remaining424
Applied Filters:
Dataforth
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureOutput TypeMounting TypeTermination StyleOutput RangeTypeInput TypeInput Range (Additional)IsolationSeriesVoltage - SupplyInput Range (Current, Voltage)
DSCA38-05
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
±10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±20mV
DSCA38-19C
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
4 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
0 ~ 20mV
DSCA43-04
GENERAL PURP. SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
±10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±4V
DSCA38-11E
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±30mV
DSCA45-01E
FREQUENCY SIGNAL CONDITIONER DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Frequency
0 ~ 0.5kHz TTL
1500V
DSCA
19 ~ 29VDC
-
DSCA38-12
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
0 ~ 10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±20mV
DSCA43-14C
GENERAL PURP. SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
4 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±4V
DSCA38-18E
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
0 ~ 30mV
DSCA38-12E
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±20mV
DSCA38-20
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
0 ~ 10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
0 ~ 33.3mV
DSCA43-11E
GENERAL PURP. SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±1V
DSCA43-17
GENERAL PURP. SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
0 ~ 10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±7V
DSCA38-04
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
±10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±30mV
DSCA45-07E
FREQUENCY SIGNAL CONDITIONER DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Frequency
0 ~ 50kHz TTL
1500V
DSCA
19 ~ 29VDC
-
DSCA38-09
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Voltage
DIN Rail
Screw Terminal
0 ~ 10V
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±30mV
DSCA47J-02E
LINEAR. THERMOC. SIG CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Temperature
-100°C ~ 300°C
1500V
DSCA
15 ~ 30VDC
-
DSCA45-03E
FREQUENCY SIGNAL CONDITIONER DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Frequency
0 ~ 2.5kHz TTL
1500V
DSCA
19 ~ 29VDC
-
DSCA47J-03E
LINEAR. THERMOC. SIG CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Temperature
0 ~ 500°C
1500V
DSCA
15 ~ 30VDC
-
DSCA45-01C
FREQUENCY SIGNAL CONDITIONER DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
4 ~ 20mA
Signal Conditioner
Frequency
0 ~ 0.5kHz TTL
1500V
DSCA
19 ~ 29VDC
-
DSCA38-13E
STRAIN GAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 80°C
Current
DIN Rail
Screw Terminal
0 ~ 20mA
Signal Conditioner
Voltage
-
1500V
DSCA
19 ~ 29VDC
±33.3mV

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.