Signal Conditioners and Isolators

Results:
913
Manufacturer
Series
Input Range (Current, Voltage)
Input Range (Additional)
Voltage - Supply
Output Range
Isolation
Operating Temperature
Features
Input Type
Type
Output Type
Termination Style
Mounting Type
Results remaining913
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesFeaturesOperating TemperatureOutput TypeMounting TypeVoltage - SupplyTermination StyleTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output RangeIsolation
2813554
3-WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Voltage
DIN Rail
24VDC
Spring Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 10V
1500V (Test)
2904960
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MACX
-
-
-
-
-
-
-
-
-
-
-
-
2904961
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MACX
-
-
-
-
-
-
-
-
-
-
-
-
2904964
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MACX
-
-
-
-
-
-
-
-
-
-
-
-
2904963
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MACX
-
-
-
-
-
-
-
-
-
-
-
-
2813570
MCR 3-WAY ISOLATING AMPLIFIER FO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MINI MCR
-
-20°C ~ 65°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
1500V (Test)
2814540
3 WAY ISOLATING AMP 4-20MA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MCR
-
-25°C ~ 60°C
Current
DIN Rail
20 ~ 30VDC
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
-
4 ~ 20mA
1500V (Test)
2924223
MACX MCR-SL-IDSI-I-SP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 60°C
Current
DIN Rail
24VDC
Screw Terminal
Signal Conditioner
Current
0 ~ 20mA
-
0 ~ 20mA
-
SC-TC-TC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
0°C ~ 55°C
Current, Voltage
DIN Rail
12 ~ 32VAC, 12 ~ 36VDC
Screw Terminal
Signal Conditioner
-
-
-
1000V
AIMI0010
PASSIVE LOOP POWERED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
-
-
-
-
-
SC-TC-TC-6
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
0°C ~ 55°C
-
DIN Rail
12 ~ 32VAC, 12 ~ 36VDC
Screw Terminal
Signal Conditioner
-
-
-
-
1000V
3B32-02
3B32 - SIGNAL CONDITIONING I/O S
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
-
-
-
-
-
-
-
2517450000
PICOPAK-CI-CO-LP-S
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-40°C ~ 70°C
Current
DIN Rail
Loop Powered
Screw Terminal
Passive Isolator
Current
4 ~ 20mA
-
4 ~ 20mA
-
SEM1600T
TEMPERATURE SIGNAL CONDITIONER F
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-30°C ~ 70°C
Current, Voltage
DIN Rail
10 ~ 32VAC, 10 ~ 48VDC
Screw Terminal
Signal Conditioner
Resistance, Temperature, Voltage
-100 ~ 200mV
0.01 ~ 10.5kOhm, -200°C ~ 1760°C
0 ~ 20mA, ±10V
-
SEM1600VI
mA / VOLTAGE SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Loop Powered
-30°C ~ 70°C
Current, Voltage
DIN Rail
10 ~ 32VAC, 10 ~ 48VDC
Screw Terminal
Signal Conditioner
Current, Voltage
±50mA, ±50V
-
0 ~ 20mA, ±10V
-
SEM1600B
LOAD CELL SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Tare
-30°C ~ 70°C
Current, Voltage
DIN Rail
10 ~ 32VAC, 10 ~ 48VDC
Screw Terminal
Signal Conditioner
Loadcell
±7.6VmV/V
-
0 ~ 20mA, ±10V
-
SEM1700
UNIVERSAL SIGNAL CONDITIONER WIT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Relay Output (2)
-30°C ~ 70°C
Current, Voltage
DIN Rail
240VAC, 20VDC
Screw Terminal
Signal Conditioner
Current, Voltage, Resistance, Temperature
±30mA, ±11V
0 ~ 480Ohm, -200°C ~ 1760°C
0 ~ 20mA, 0 ~ 10V
-
DSCA31-03
SIGNAL CONDITIONER V-IN DIN RAIL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DSCA
-
-40°C ~ 80°C
Voltage
DIN Rail
15 ~ 30VDC
Screw Terminal
Signal Conditioner
Voltage
±10V
-
±10V
1500V
DSCA33-06
SIGNAL CONDITIONER TRUE RMS DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DSCA
-
-40°C ~ 80°C
Voltage
DIN Rail
19 ~ 29VDC
Screw Terminal
Signal Conditioner
Current
0 ~ 1A
-
0 ~ 10V
1500V
DSCT32-01
I-IN 4-20MA TRANSMITTER DIN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DSCT
-
-40°C ~ 80°C
Current
DIN Rail
Loop Powered
Screw Terminal
Signal Conditioner
Current
4 ~ 20mA
-
4 ~ 20mA
1500V

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.