Siemens

Siemens

Siemens is a global technology powerhouse that operates in various sectors, including industry, energy, healthcare, and infrastructure. With a history dating back over 170 years, Siemens has established itself as a leader in innovation and sustainability. The company offers a wide range of products, solutions, and services, ranging from automation and digitalization to electrification and mobility. Siemens' industrial automation systems help optimize manufacturing processes, while their energy solutions focus on efficient power generation and distribution. In the healthcare sector, Siemens provides advanced medical imaging equipment and clinical IT systems. Additionally, Siemens is involved in developing smart infrastructure solutions to support sustainable development in cities and communities. With a strong commitment to technological advancement and social responsibility, Siemens continues to drive progress and shape the future across multiple industries.

Signal Conditioners and Isolators

Results:
36
Filters
Applied Filters:
Siemens
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesFeaturesOperating TemperatureMounting TypeVoltage - SupplyTermination StyleTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output TypeOutput RangeIsolation
3RS70051FW00
SWTCHBL MULTI-RANGE CNVRTR, 24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24 ~ 240VAC/DC
Screw Terminal
Signal Conditioner
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
Current, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
300V
3RS70201ET00
4-20MA TO 4-20MA CNVRTR, PASSIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
-
Screw Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70202ET00
4-20MA TO 4-20MA CNVRTR, PASSIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
-
Spring Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70021AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
50V
3RS70001DE00
0-10V TO 4-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Current
4 ~ 20mA
50V
3RS70031AE00
4-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
50V
3RS70031CE00
4-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
0 ~ 20mA
50V
3RS70032CE00
4-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
0 ~ 20mA
50V
3RS70032AE00
4-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
50V
3RS70001CE00
0-10V TO 0-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Current
0 ~ 20mA
50V
3RS70021CE00
0-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Current
0 ~ 20mA
50V
3RS70031DE00
4-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70002AE00
0-10V TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Voltage
0 ~ 10V
50V
3RS70022CE00
0-20MA TO 0-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Current
0 ~ 20mA
50V
3RS70002DE00
0-10V TO 4-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Current
4 ~ 20mA
50V
3RS70032DE00
4-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70021DE00
0-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70022DE00
0-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Current
4 ~ 20mA
50V
3RS70022AE00
0-20MA TO 0-10V CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
Voltage
0 ~ 10V
50V
3RS70002CE00
0-10V TO 0-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
3RS7
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
Current
0 ~ 20mA
50V

About  Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.