Signal Conditioners and Isolators

Results:
911
Manufacturer
Series
Input Range (Current, Voltage)
Input Range (Additional)
Voltage - Supply
Output Range
Isolation
Operating Temperature
Features
Input Type
Type
Output Type
Termination Style
Mounting Type
Results remaining911
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureMounting TypeVoltage - SupplyTermination StyleOutput TypeSeriesTypeInput TypeInput Range (Current, Voltage)Input Range (Additional)Output RangeIsolation
3RS70021DE00
0-20MA TO 4-20MA CNVRTR, 24VAC/D
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Current
3RS7
Isolation Amplifier
Current
0 ~ 20mA
100 Ohm
4 ~ 20mA
50V
857-818
TEMPERATURE SIGNAL CONDITIONER F
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
Current, Voltage
857
Signal Conditioner
Temperature
-
-
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
3RS70251FE00
SWTCHBL MULTI-RANGE CNVRTR, 24VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Current, Voltage
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
0 ~ 20mA, 0 ~ 10V (Configurable)
50V
857-401
ISOLATION AMPLIFIER; CURRENT AND
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
Current, Voltage
857
Isolation Amplifier
Current, Voltage
±20mA, 0 ~ 30V (Configurable)
0 ~ 100kOhm
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
3RS70052KE00
SWITCHABLE MULTI-RANGE CNVRTR, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
-
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
-
50V
3RS70052FE00
SWITCHABLE MULTI-RANGE CNVRTR, 2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Spring Terminal
Current, Voltage
3RS7
Isolation Amplifier
Current, Resistance, Voltage
0 ~ 20mA, 0 ~ 10V (Configurable)
100 Ohm, 330k Ohm
0 ~ 20mA, 0 ~ 10V (Configurable)
50V
2813512
MCR 3-WAY ISOLATING AMPLIFIER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 65°C
DIN Rail
24VDC
Screw Terminal
Current
MINI MCR
Signal Conditioner
Voltage
0 ~ 10V
-
0 ~ 20mA
1500V (Test)
2905279
SINGLE-CHANNEL 2-WAY ISOLATOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 85°C
DIN Rail
Loop Powered
Spring Terminal
Current
MACX MCR
Passive Isolator
Current
0 ~ 20mA
-
0 ~ 20mA
-
2902017
MINI MCR-2-POT-UI-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
Screw Terminal
Current, Voltage
MINI MCR
Signal Conditioner
Resistance
-
0.1 ~ 100kOhm
0 ~ 20mA, 0 ~ 10V (Configurable)
-
857-420
ISOLATION AMPLIFIER; CURRENT INP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
Current, Voltage
857
Isolation Amplifier
Current
0 ~ 20mA (Configurable)
0 ~ 50Ohm
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
857-809
POTENTIOMETER SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
Current, Voltage
857
Signal Conditioner
Resistance
-
10 ~ 100kOhm
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)
3RS70001DE00
0-10V TO 4-20MA CNVRTR, 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
24VAC/DC
Screw Terminal
Current
3RS7
Isolation Amplifier
Resistance, Voltage
0 ~ 10V
330k Ohm
4 ~ 20mA
50V
857-451
PASSIVE ISOLATOR, 1-CHANNEL; CUR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
-
Spring Terminal
Current
857
Passive Isolator
Current
0 ~ 20mA (Configurable)
-
0 ~ 20mA (Configurable)
3000V (Test)
3RS70202ET00
4-20MA TO 4-20MA CNVRTR, PASSIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
DIN Rail
-
Spring Terminal
Current
3RS7
Isolation Amplifier
Current
4 ~ 20mA
100 Ohm
4 ~ 20mA
50V
15641.2
SIGNAL CONDITIONER
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-20°C ~ 55°C
DIN Rail
24V
Screw Terminal
Current, Voltage
-
-
Resistance
-
1 ~ 20kOhm
22mA, 11V
-
857-531
JUMPFLEX TRANSDUCER; THRESHOLD V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
-
857
-
Current, Voltage
±20mA, 0 ~ 30V (Configurable)
0 ~ 100kOhm
-
2500V (Test)
2902030
MINI MCR-2-U-I4-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
Screw Terminal
Current
MINI MCR
Signal Conditioner
Voltage
0 ~ 10V
-
4 ~ 20mA
-
2901999
MINI MCR-2-I-I-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
Screw Terminal
Current
MINI MCR
Isolation Amplifier
Current
0 ~ 20mA
-
0 ~ 20mA
-
2902003
MINI MCR-2-I4-U-PT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-40°C ~ 70°C
DIN Rail
24VDC
Screw Terminal
Voltage
MINI MCR
Signal Conditioner
Current
4 ~ 20mA
-
0 ~ 10V
-
857-500
FREQUENCY SIGNAL CONDITIONER; CU
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
DIN Rail
24VDC
Spring Terminal
Current, Voltage
857
Signal Conditioner
Frequency
-
0.1 ~ 120kHz, 0 ~ 10kOhms
0 ~ 20mA, 0 ~ 10V (Configurable)
2500V (Test)

Signal Conditioners and Isolators

Signal conditioners and isolators are electronic devices used in industrial applications to enhance the performance and safety of measurement systems. Signal Conditioners: Signal conditioners are used to convert signals from one level or type to another, typically for sensor measurements. These devices help to improve the accuracy and reliability of the measurement system by amplifying, filtering, or linearizing the signals. Signal conditioners can be used with various types of sensors, such as thermocouples, RTDs, strain gauges, and pressure transducers. Signal conditioners can be categorized based on various parameters, such as input type, output type, isolation voltage, and additional features. Input types could include voltage, current, or resistance, while output types could be voltage, current, or frequency. Isolation voltage refers to the level of electrical isolation between the input and output circuits. Additional features could include surge protection, signal inversion, or programmable settings. Isolators: Isolators are devices that separate or isolate one circuit from another in regard to power. They help to prevent ground loops, reduce noise, and provide electrical isolation between different parts of a system. Isolators can be passive or active, depending on whether they require an external power supply. Isolators can be categorized into various types, such as isolation amplifiers, passive isolators, and signal conditioners. Isolation amplifiers use transformer or optical techniques to provide galvanic isolation between different circuits. Passive isolators, on the other hand, rely on magnetic or capacitive coupling to provide isolation. Signal conditioners can also act as isolators, providing electrical isolation between the input and output circuits. Isolators can also be defined by various parameters, such as input voltage range, output voltage range, isolation voltage, and common mode rejection ratio (CMRR). Input voltage range refers to the range of voltages that can be applied to the input circuit, while the output voltage range refers to the range of voltages that can be obtained from the output circuit. The isolation voltage indicates the level of electrical isolation provided by the isolator, while CMRR represents the ability of the isolator to reject common-mode signals. In summary, signal conditioners and isolators are electronic devices used in industrial applications to improve the accuracy, reliability, and safety of measurement systems. Signal conditioners convert signals from one level or type to another, while isolators provide electrical isolation between different parts of a system. These devices can be categorized based on various parameters, such as input type, output type, isolation voltage, and extra features, and are critical components in many industrial applications.