Thermocouples, Temperature Probes

Results:
2,373
Manufacturer
Series
Temperature Range
Length - Lead Wire
Element Type
Terminal Type
Conductor Type
Operating Temperature
Qualification
Sensor Type
Output Type
Grade
Results remaining2,373
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesElement TypeTemperature RangeLength - Lead WireConductor TypeTerminal Type
E52-P20C-N D=4.8
RTD L=20CM THERMO WELL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
Pt100
0 ~ 400°C
-
3 Conductor System
Enclosed Terminals
LT1052CN
MICROPOWER THERMOCOUPLE COLD JUN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
E52-CA6AFD1S1 1M
THERMOCOUPLE K TYPE 1MM DIA .5M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0°C ~ 650°C
3.281' (1m)
Grounded
Exposed Lead Wires
ITTUP400A
TEMP PROBE PT100 6X400MM 1/4"NPT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ITTU
Pt100
-200°C ~ 850°C
-
3 Conductor System
Enclosed Terminals
E52-CA20B-N D=3.2
T-COUPLE TYPE K L=20CM Y-STYLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 400°C
-
Non-Grounded
Exposed Terminals
LTPCTFA25MDSITX01
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
LTPCTAA20MHSITX01
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
*
-
-
-
-
-
LTPCTGA30MDBITX01
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
LTP
Thermistor
-40 ~ 150°C
-
Non-Grounded
Connector
E52-PR50C-N D=15 PT1
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
Pt100
-200°C ~ 450°C
-
3 Conductor System
Enclosed Terminals
E52-P5AY-40 4M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
Pt100
-50°C ~ 180°C
13.123' (4m)
Non-Grounded
Exposed Lead Wires
E52-IC50B-N D=6.4
T-COUPLE TYPE J L=50CM Y-TYPE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
J - Type
0 ~ 1050°C
-
Non-Grounded
Exposed Terminals
E52-CA35A D=8 8M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 1050°C
26.247' (8m)
Non-Grounded
Exposed Lead Wires
E52-CA20C-6.4
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 1000°C
-
Non-Grounded
Enclosed Terminals
E52-IC15AY D=1 4M
T-COUPLE TYPE J L=15CM 1M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
J - Type
0 ~ 350°C
3.281' (1m)
Non-Grounded
Exposed Lead Wires
E52-IC20AY D=4.8 1M
T-COUPLE TYPE J L=20CM 1M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
J - Type
0 ~ 350°C
3.281' (1m)
Non-Grounded
Exposed Lead Wires
E52-CA15AY D=3.2 NETU 2M
T-COUPLE K L=15CM 2M HEAT RES
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 900°C
6.562' (2m)
Non-Grounded
Exposed Lead Wires
E52-CA15ASY 4M
T-COUPLE TYPE K L=150MM 4M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 400°C
13.123' (4m)
Non-Grounded
Exposed Lead Wires
E52-CA15ASY 2M
T-COUPLE TYPE K L=150MM 1M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
K - Type
0 ~ 400°C
6.562' (2m)
Non-Grounded
Exposed Lead Wires
E52-IC1DY W1/4 1M
T-COUPLE TYPE J 1/4 THREAD 1M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
J - Type
0 ~ 350°C
3.281' (1m)
Grounded
Exposed Lead Wires
E52-THE-E5L 100-200 C0.5M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E52
Thermistor
100°C ~ 200°C
19.68" (500mm)
Non-Grounded
Exposed Lead Wires

Thermocouples, Temperature Probes

Thermocouples and Temperature Probes are specialized devices used to measure temperature by exploiting the principle of thermoelectric effect. They consist of two dissimilar conductors that form junctions at different temperatures, generating a voltage proportional to the temperature difference. These temperature sensors come in various element types, including IC (Integrated Circuit), J-type, K-type, Pt100, T-type, and thermistor. Each element type is designed to accommodate different temperature ranges and offer specific advantages for particular applications. For example, K-type thermocouples are widely used for general-purpose temperature measurements, while Pt100 sensors provide higher accuracy and stability. The temperature range covered by thermocouples and temperature probes is extensive, with measurements possible from -200°C to 1350°C. This wide range enables their application in diverse industries, such as automotive, aerospace, food processing, and scientific research. In addition to the element types and temperature range, the lead wire lengths of these sensors vary. They can range from shorter lengths, such as 3.70" (94.00mm), to longer lengths like 26.247' (8m). This flexibility in lead wire lengths allows for customization based on specific installation requirements and environmental conditions. Thermocouples and Temperature Probes are widely used due to their durability, reliability, and ability to withstand harsh environments. Their versatility in measuring temperature across a broad range makes them indispensable tools in various industries where accurate temperature monitoring is critical. In summary, Thermocouples and Temperature Probes utilize the thermoelectric effect to measure temperature. With different element types and temperature ranges, they cater to a wide range of applications. Their varying lead wire lengths provide flexibility for installation, making them essential tools for accurate temperature measurement in diverse industries.