Square D JCK Series, Time Delay Relays

Results:
76
Manufacturer
Series
Delay Time
Voltage - Supply
Function
Timing Adjustment Method
Timing Initiate Method
Circuit
Contact Rating @ Voltage
Termination Style
Mounting Type
Relay Type
Results remaining76
Applied Filters:
Square D JCK
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesDelay TimeCircuitContact Rating @ VoltageMounting TypeFunctionTermination StyleVoltage - SupplyRelay TypeTiming Adjustment MethodTiming Initiate Method
9050JCK11V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Sec ~ 10 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
On-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK18V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.6 Min ~ 60 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
On-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK16V14
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Min ~ 10 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
On-Delay
Plug In
24VAC/DC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK25V14
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
1.8 Sec ~ 180 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
24VAC/DC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK2F15V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
Fixed, 15 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Fixed
Input Voltage
9050JCK17V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Min ~ 30 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
On-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK24V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
1.2 Sec ~ 120 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK25V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
1.8 Sec ~ 180 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK41V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Sec ~ 10 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
One Shot
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK22V14
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Sec ~ 30 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
24VAC/DC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK21V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Sec ~ 10 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK24V14
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
1.2 Sec ~ 120 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
24VAC/DC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK22V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Sec ~ 30 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK42V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Sec ~ 30 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
One Shot
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK23V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.6 Sec ~ 60 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK21V14
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Sec ~ 10 Sec
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
24VAC/DC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK28V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.6 Min ~ 60 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK26V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.1 Min ~ 10 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK27V20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Min ~ 30 Min
DPDT (2 Form C)
10A @ 240VAC
Socketable
Off-Delay
Plug In
120VAC
Mechanical Relay
Hand Dial
Input Voltage
9050JCK27PTV20
TIMING RELAY, TYPE JCK, PLUG IN,
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Square D JCK
0.3 Min ~ 30 Min
-
-
Socketable
Off-Delay
Plug In
120VAC/DC
Mechanical Relay
Hand Dial
Input Voltage, Trigger Signal

About  Time Delay Relays

Time Delay Relays (TDRs) are electromechanical devices utilized in various applications to enable the control of large loads using a smaller control signal. These relays incorporate a built-in time delay mechanism, allowing for precise timing in triggering the relay's operation. TDRs offer a wide range of functions to accommodate different timing requirements and operational scenarios. Some of the common functions provided by TDRs include: Interval Function: In this mode, the relay operates for a specified duration of time after receiving a control signal, and then deactivates until the next signal is received. It is often used for cyclic operations or periodic tasks. Off-Delay Function: With the off-delay function, the relay remains energized for a predetermined period after the control signal is removed. This delay ensures that the load remains powered for a specific duration before being turned off. On-Delay Function: The on-delay function introduces a time delay between the reception of the control signal and the activation of the relay. This delay allows for a temporary pause before the load is energized. One-Shot Function: In one-shot mode, the relay triggers a single output pulse of a defined duration when the control signal is received. This function is commonly used for momentary operations or as a pulse generator. Programmable (Multi-function) TDRs: These TDRs provide flexibility by offering multiple programmable timing functions in a single device. Users can configure the desired timing parameters according to their application requirements. Repeat Cycle Function: With the repeat cycle function, the relay alternates between on and off states at regular intervals, allowing for repetitive operation. Twin Timer Function: Twin timer TDRs feature two separate adjustable timers that operate independently, enabling more complex timing sequences or dual-output operations. Signal On-Off-Delay Function: This function combines both on-delay and off-delay functions, allowing for control of the load based on specific time periods for activation and deactivation. Star/Delta Controller: The star/delta controller function is commonly used in motor control applications. It provides a specific starting sequence for motors, optimizing their performance and reducing the initial high-current demand during startup. Time Delay Relays are versatile devices that find applications in various industries, including automation, control systems, HVAC, lighting, and motor control. They offer precise timing control and serve as reliable tools for coordinating the operation of large loads with smaller control signals.